Aún sin autorAsumirla
Versión 2Actualizado 3 min de lectura
- Licencia
- CC0 1.0 (dominio público)Adaptado de www.epa.gov
- Idiomas
- English
- Temas
- SaludNaturaleza
This chapter of EPA’s mold course covers general remediation issues in four lessons: dry quickly, assess the mold problem, make a remediation plan, and follow remediation procedures.
Lesson 1: dry quickly
Dry wet or damp items before mold grows if possible. In most cases mold will not grow if items are dried within 24 to 48 hours.
| Material | What to do |
|---|---|
| Carpet and backing | Remove water with a wet vacuum, pull carpet and pad off the floor, and dry with fans; a dehumidifier helps |
| Concrete or cinder block | Water-extraction vacuum; dehumidifiers, fans and heaters speed drying |
| Hard flooring (linoleum, tile, vinyl) | Vacuum or damp wipe with mild detergent, scrub if needed, dry; dry wet under-flooring |
| Plastics and metals | Vacuum or damp wipe with water and mild detergent, then dry |
| Upholstered furniture | Water-extraction vacuum, fans, dehumidifiers; if valuable, consider a professional |
| Drywall | May be dried in place if there is no obvious swelling and seams are intact, ventilating the wall cavity; otherwise remove |
| Wood | Remove moisture at once and dry with dehumidifiers, fans and gentle heat; treated wood can be cleaned with mild detergent; pry off wet paneling |
| Drapes | Follow the maker’s cleaning instructions |
Some water-damaged items may have to be discarded: ceiling tiles, cellulose and fiberglass insulation, drywall and gypsum board, and books and papers. For valuable items, consult a restoration expert. These guidelines are for clean water. If sewage or chemical or biological pollutants are known or suspected, OSHA requires protective equipment and containment, and an experienced professional should be consulted. Do not use fans until the water is known to be clean.
Lesson 2: assess the problem

Mold on gypsum wallboard.
Before planning, assess the size and extent of the mold and any continuing moisture problems. Jobs are generally small (less than 10 square feet), medium (10 to 100 square feet) or large (more than 100 square feet). A remediation manager should be chosen for medium or large jobs, and a health and safety professional may be involved. Questions to ask include whether moisture problems exist, whether materials have been wet more than 48 hours, whether hidden water or condensation is likely, whether occupants report musty odors or health problems, whether materials are visibly damaged, whether maintenance has lapsed, and whether the building was recently remodeled.
Remediation can increase workers’ exposure to mold unless protective equipment is used. Do not touch mold with bare hands, get it in your eyes or breathe it in. The minimum equipment is an N-95 respirator, gloves and goggles. Workers with health concerns should check with a doctor first.

An N-95 disposable respirator used to protect against fungal exposure.
Lesson 3: the remediation plan
The first priority is the health and safety of occupants and workers. A plan varies with the job’s size and complexity and may need updating. It should state whether containment is needed, what protective equipment will be used, how the moisture problem will be fixed so mold does not return, and how moldy materials will be removed without spreading mold.
Lesson 4: procedures
Methods depend on the size of the moldy area and the materials. Budget may matter, and the course presents one approach; some professionals use others. When possible, work during off-hours when occupants are less likely to be affected.

Damp wiping a surface with water and a small amount of detergent.
- Wet vacuum: collects water from floors, carpets and hard surfaces, but only while materials are still wet, otherwise it may spread spores. It will not dry carpets, which must be pulled up and dried, and the padding too. Clean and dry the tank, hoses and attachments afterward.
- Damp wipe: mold can usually be removed from hard surfaces with water and detergent. Dry surfaces quickly. Porous wet materials with mold may have to be discarded, since mold infiltrates them and removing it completely may be impossible. Mold can also stain.
- HEPA vacuum: recommended for final cleanup after materials are dry and contaminated materials are removed, and for dust settled outside the work area. Workers wear protective equipment when changing the filter, and the filter and contents go into well-sealed plastic bags.

A HEPA vacuum.
Mold-contaminated materials that cannot be saved should be double-bagged in polyethylene bags of at least 6-mil thickness, and can usually be thrown out as ordinary construction waste. Sealing them before removal limits the spread of spores. Large items with heavy mold growth should be covered with polyethylene sheeting and sealed with duct tape before leaving the containment area.
Sources
- U.S. Environmental Protection Agency, “Mold Course Chapter 4: General Remediation Issues”, https://www.epa.gov/mold/mold-course-chapter-4 ; rewritten in hubnx's own words.
Comentarios