For decades, many structural engineers assumed that a tornado was too intense for a building to be designed against. The 2024 International Building Code (IBC) now contains, for the first time, a section on tornado resiliency. The change traces back to NIST researchers who questioned how tornadoes were rated, and in an interview on NIST's Taking Measure blog, two of them, Long Phan and Marc Levitan, explained how it happened.
Over 1,200 tornadoes touch down in the U.S. every year, causing dozens of deaths. The IBC is a reference document widely used to write local building-code laws, so a tornado section in it reaches far beyond one agency's research. At the time of the interview, Phan and Levitan were finalists for the Samuel J. Heyman Service to America Medal, which recognizes federal employees for outstanding public service. Phan leads the Structures Group at NIST, where he has worked for nearly 40 years studying how buildings and structures respond to extreme hazards. Levitan is a wind and structural engineer and the lead research engineer for the National Windstorm Impact Reduction Program.
Why a roof comes off
Wind blowing over a roof accelerates, which creates uplift pressure, much as air flowing over an airplane wing does. That happens in every windstorm. Tornadoes add two more effects:
- strong updrafts near the core of the tornado, which increase the uplift
- lower atmospheric pressure in the core: when the tornado passes over a relatively well-sealed building, the higher pressure inside can push up on the roof and push out on the walls
The key to keeping the roof on, Levitan said, is a strong load path, meaning every piece is connected from each shingle down to the foundation. For a typical-size home he put the cost on new construction at maybe $500 or $1,500 extra.
Most tornadoes are not the worst kind. Wind speeds of 130 mph or less do a lot of damage to a house but typically do not destroy the whole building. Levitan named a combination of factors that make tornadoes dangerous: warning time averages only about 13 minutes, sometimes much less, and until very recently the building code had no requirements for tornado loads.
The Jarrell tornado and the Fujita scale
There was no outdated tornado chapter to revise, Phan said: before this, nothing existed, and a brand-new provision had to be written. The turning point for him was the 1997 tornado at Jarrell, Texas. The National Weather Service rated it F5, the highest on the Fujita scale, which estimates wind speed from the damage a tornado causes and assumes that more damage means higher wind speed. Phan, an engineer with experience in structural failure, doubted that extreme wind speed was what caused the damage.
If the scale overstated typical tornado winds, engineers had reason to give up, thinking a building would have to be "a stone pyramid" to survive one. A year after the Jarrell tornado Phan wrote an article with Emil Simiu showing that the wind speed behind the damage was much lower than the scale said. NIST then funded Texas Tech University to calculate wind speeds more accurately, which led to the Enhanced Fujita scale, adopted by the Weather Service in 2007. It takes new details into account, such as construction quality: a poorly built structure is destroyed by a weaker tornado, and in extreme cases like Jarrell that can mean a rating of 3 instead of 5.
The Enhanced Fujita scale runs from EF0, with modest damage such as tree branches and gutters, to EF5, where all but the most well-built homes are destroyed and perhaps only a slab is left. Phan said 97 percent of the tornadoes in the country are EF2 or lower, wind speeds that can easily be designed for.
Joplin and the new code

Damage from the 2011 Joplin, Missouri, tornado, where homes were leveled by winds of 200 mph (photo: Jace Anderson/FEMA).
The Joplin, Missouri, tornado in 2011 was an EF5, with winds the Weather Service estimated at 200-plus mph. It struck the heart of a town of about 50,000 people, damaged or destroyed about a third of the city and nearly 8,000 buildings, and caused 161 deaths and $3 billion in costs, making it the single deadliest and single costliest tornado since official records began in 1950. Two days after it hit, NIST had a team on the ground in Missouri to work out how the buildings failed.
The study's technical report came out in 2014 with recommendations, including working toward new codes and standards, and NIST began a long-term follow-up project. A decade of NIST-led tornado research produced new tornado hazard maps for the U.S. and a chapter on tornado load requirements in the American Society of Civil Engineers (ASCE) standard for minimum design loads on buildings, ASCE 7. NIST then worked with ASCE and the Federal Emergency Management Agency to propose changes that brought those requirements into the 2024 IBC.
The new code asks many conventional buildings to resist tornadoes, but only certain important ones: Risk Category 3, such as schools, nursing homes and high-occupancy buildings like theaters, and Risk Category 4, essential facilities such as fire and police stations, hospitals and EMS facilities. Phan called the result immensely satisfying and "beyond our wildest imagination," and said that in 2014 he did not know the effort would get this far.
What comes next
Levitan said there is more to learn to fill gaps and improve tornado load requirements in future editions, and that states and localities need support to understand and adopt the model code. Phan is leading a project on how climate may affect future codes and standards. Buildings typically last 50 or 100 years, and by then hazards may differ; tornadoes might be more intense, and higher temperatures could affect how construction materials perform.
Sources
- National Institute of Standards and Technology, Taking Measure blog, "NIST Research Is Setting the Standard to Help Buildings Withstand Tornadoes" (https://www.nist.gov/blogs/taking-measure/nist-research-setting-standard-help-buildings-withstand-tornadoes); photo credit as printed on the page; rewritten in hubnx's own words.