Автора пока нетВзять себе
- Лицензия
- CC0 1.0 (общественное достояние)По материалам www.nist.gov
- Языки
- English
- Темы
- Наука
The national ballistics database has produced more than 68,000 hits, according to the Bureau of Alcohol, Tobacco, Firearms, and Explosives (ATF), and its usefulness depends on every lab imaging cartridge cases the same way. NIST has released a downloadable interactive control chart to let labs check that.
The database
The National Integrated Ballistics Information Network (NIBIN) links about 150 specialized systems in U.S. federal, state and local crime labs. Labs run images of spent bullets or cartridge cases through it and look for “hits,” potential matches with other evidence, which specialists then confirm by manual inspection. The 68,000-plus hits date from the project’s start in the 1990s. A NIST physicist in the Physical Measurement Laboratory (PML) called it a powerful way to link firearms, suspects and crimes.
Every NIBIN lab uses a common imaging and correlation system called IBIS. For the comparisons to work, microscope images must be acquired consistently. Photos taken on different days by different labs may differ in contrast or lighting intensity, but the same cartridge should give the same image today, tomorrow or six months later.
What NIST did
- Mid-2000s. The ATF asked PML staff to design a way for NIBIN labs to calibrate their imagers. NIST made a “standard bullet” and a “standard cartridge case,” with markings like those on real evidence but a surface topography known to a high degree, and master images were taken at the ATF National Laboratory Center. A lab images the standard at regular intervals and compares it with the master, getting a correlation score. A sufficiently high score shows image quality is under control.
- Late 2000s. NIST was asked how high that score must be. PML ran a study with 19 experts from 13 crime labs and produced a chart for the imaging model then in use.
- Then a new model. IBIS released a new imager, the BRASSTRAX machine, essentially a black box with a camera and lights. It has double the pixel resolution of the previous system, 3D capability, and is used only for microscopic measurement of spent cartridge cases. Because it uses the same correlation software, images from the old and new systems can be compared in the database. NIST notes that mention of commercial products is for information only and is not an endorsement.

Close-ups of standard cartridge cases showing differences between the older (left) and newer (right) imaging systems and the effect of lighting. The top two photos used oblique lighting, the bottom two ring lighting. They show the breech face impressions. Image from NIST’s page.
The new study
The imager photographs three key markings on a spent cartridge case:
- the firing pin impression, made when the pin strikes the primer and ignites the gunpowder;
- the breech face marking, a roughness profile imprinted on the head of the case when recoil thrusts it against the back wall of the gun, which one NIST researcher called a kind of fingerprint for the weapon;
- the ejector mark, made as the spent case is ejected.

Anatomy of a firearm, showing the breech area where toolmarks are imparted on cartridge cases during firing. Image from NIST’s page.
PML asked 14 ballistics examiners using BRASSTRAX machines at 11 NIBIN laboratories to image NIST’s Standard Cartridge Case (SRM 2461) at regular intervals for about a year. Each image was scored against master images taken on ATF’s own BRASSTRAX machine.
Correlation scores were higher on average with the new system. The gains were fairly small for the breech face and ejector markings but significant for the tiny firing pin impressions, so PML recommended a much higher acceptance limit for firing pin images. Forensics specialists can enter data about their images in a spreadsheet and get immediate feedback on whether they are within acceptable limits. PML also set uncertainty levels for the firing pin and breech face markings, which investigators can use to judge their confidence in a match. The researchers hope the chart will help technicians find more database hits. The work was supported by the National Institute of Justice and the Law Enforcement Standards Office at NIST.
Sources
- National Institute of Standards and Technology, New Ballistics Control Chart for Forensic Imaging; the study is Vorburger and colleagues, The Second National Ballistics Imaging Comparison (NBIC-2), Journal of Research of NIST, cited on that page; rewritten in hubnx's own words.
Комментарии