Time series of the demodulated signal as a steel Allen key is moved near the magnetometer

Signal spike as a steel Allen key approaches the magnetometer; the quadrature channel stays near zero. Figure from Williams et al., CC BY 4.0.

Wave a steel Allen key near this magnetometer and its signal spikes, while the green light that excites the sensor and the red glow it gives back are both visible to the naked eye. The device, described in an arXiv paper, is a nitrogen-vacancy (NV) diamond magnetometer for outreach events and undergraduate labs that swaps the usual green laser for a high-power LED, with about 370 mW of optical power. The authors listed on the paper's supplementary material are Hollis Williams, Alex Newman, Stuart Graham, Colin Stephen and Gavin Morley.

Why an LED

Quantum technology is growing quickly, and universities want teaching demonstrations to match. NV centers, defects in diamond where a nitrogen atom sits next to a gap in the crystal, are stable qubits at room temperature, so they suit such demonstrations. Using optically detected magnetic resonance (ODMR), students can watch spin-state dynamics, Zeeman splitting and the basics of magnetometry.

Cheaper designs exist, among them a mostly 3D-printed set-up costing well under €250 and the open-source Uncut Gem kit. The authors say theirs does not compete on price. It aims instead for safety, portability and a signal so clear that it is easy to show. An LED needs no laser safety procedures or alignment, so it suits events with little supervision, and the fluorescence it excites is bright enough to see without instruments.

How it works

The LED's light passes through a short hexagonal rod that evens it out, then a right-angle prism that sends it onto a millimetre-scale diamond with many NV centers. The prism and rod also bring the red fluorescence back to a long-pass filter and a photodiode. The diamond is bonded to a reflective metal pad on a custom circuit board, directly above an etched single-turn loop that carries the microwaves, and two small block magnets supply a bias field of about 1 mT. No lenses are needed, so there is little to align.

When the microwave frequency matches the spin transitions of the NV centers, the fluorescence dips; that is an ODMR resonance. The bias field splits the resonances into a pair. A digital lock-in amplifier built on an open-source Red Pitaya board picks the signal out of the noise, and students watch it in a graphical interface that shows how settings such as modulation, time constant and LED current change the signal. Because the microwave frequency is modulated, the lock-in output looks like the derivative of the dip, but the resonance frequencies are the same.

ODMR spectrum measured with frequency-modulation detection

A measured ODMR spectrum. The dashed line marks the working point, where the response is steepest. Figure from Williams et al., CC BY 4.0.

What it can do

  • Demonstration. The whole set-up packs into two small plastic boxes and can be put back together in a few minutes. At a physics department event, students watched the fluorescence on a laptop while magnetic objects were brought near.
  • Calibration. Placed inside a Helmholtz coil, the lock-in signal rose in direct proportion to the coil current, so the output voltage can stand in for magnetic field strength.
  • Sensitivity. The noise floor is about 1 μT/√Hz, poor compared with leading NV magnetometers but acceptable given the simplifications. The signal at 50 Hz is the lab's mains power.

Calibration of the magnetometer using a Helmholtz coil

Lock-in magnitude against coil current (blue circles) with a linear fit (dashed line). Figure from Williams et al., CC BY 4.0.

Sensitivity of the LED magnetometer against frequency

Sensitivity against frequency: the black line has the microwaves on a resonance, the blue line far from one. The instrument cannot see changes faster than about 100 Hz. Figure from Williams et al., CC BY 4.0.

Building and teaching with it

The estimated cost is around $4500, and the diamond alone is a large part of it: one suitable Element Six diamond is around $2000. The authors suggest cheaper filters might be used, and that an LED built into the circuit board could cut costs. Microdiamonds are far cheaper, but with this simple optics they would broaden the spectrum and reduce sensitivity. The paper gives a parts list, circuit-board files and assembly notes in its supplement.

For a 2 to 3 hour teaching lab, the supplement outlines an exercise: record a spectrum with no bias field and find the zero-field splitting, apply magnets and adjust them until two resonances separate, measure their spacing to estimate the field, and repeat with other magnet positions to judge reproducibility and uncertainty. Suggested extensions include optimising LED and microwave power, finding bias-field orientations that show all eight peaks, shrinking the design and rotating the device in the Earth's magnetic field.

Sources

  • H. Williams, A. Newman, S. Graham, C. Stephen and G. Morley, "A portable LED-based diamond magnetometer for outreach and teaching labs", arXiv (https://arxiv.org/abs/2512.03106), licensed CC BY 4.0. Changed here: condensed and rewritten in hubnx's own words; equations, the references and most of the supplement left out; figures are the paper's own, reproduced from it and credited in their captions.

Комментарии

Spinner Logo

Ещё на тему «Образование»

Автор: Abdul Ariwoola
Random article
Автор: Hub Nexus editorsПросмотры: 282
A demo for the Hub Nexus content editor, showing what could be created, and at the same time teaching how to create them with each syntax. It follows general markdown syntax, gfm, and more advanced like various charts and graphs code syntax.
Автор: Hub Nexus Nomad
The Success Podcast Myth & The Illusion of Control
CC BY-SA 4.0
Network programming under UNIX is relatively simple in C. This guide assumes you already have a good general idea about C, UNIX and networks. ## A simple client To start with, we'll look at one of the simplest things you can do: initialize a stream connection and receive a message from a remote serv
CC BY 4.0
Rate Laws