Перейти к содержимому
Hub Nexus

Автора пока нетВзять себе

Версия 2Обновлено 3 мин чтения

Поддержка

A transition edge sensor (TES) is a superconducting detector that can count the photons in a single pulse of light, and researchers at NIST showed it can do so for as many as 1,000 photons, with an accuracy limited mainly by the quantum noise of the laser. Until then, accurate counts above approximately 50 photons had not been achieved.

A micrograph in which the TES, an orange-and-green square, sits between two bright gold electrodes

At the center of this micrograph, the TES is the orange-and-green square between two bright gold electrodes. Its dimensions are 25 X 25 μm. Image from NIST's page.

Why it matters

The findings, which were being prepared for publication, could eventually be used in quantum information processing, telecommunications and optical metrology at low light levels, where information is carried in numbers of photons that can be readily detected. Many detectors sense single-photon pulses, and some, including the TES, can resolve a few tens of photons. The new research from PML extends the range to 1,000 and sharply reduces the measurement uncertainty. Thomas Gerrits of PML's Quantum Electronics and Photonics Division said that when the uncertainty is low enough and detection efficiency is close to unity, detection can decode information encoded in the photon number of a pulse.

How the sensor works

This TES is a tungsten film 20 nm thick on a silicon substrate, and the whole device measures 25 X 25 μm. It is cooled below the critical temperature of the film, but a small voltage keeps the film in the middle of its superconducting transition, so that it is neither a superconductor nor a conventional conductor. Each photon that strikes it is absorbed, heating the film and raising its resistance. When very many photons arrive, the heat saturates the device and pushes it past the transition edge into the normal, non-superconducting regime.

The new measurement

The PML/JQI team kept the TES near 140 mK and hit it with bright laser pulses at a wavelength of 1550 nm and a frequency of 1 kHz. Instead of measuring the change in resistance, as is done for faint pulses, they measured the thermal relaxation time: how long the sensor takes to shed its heat and return to the upper edge of the transition region. That time proved a remarkably sensitive indicator of photon number up to about 1,000. For brighter pulses the substrate heats substantially and numbers cannot be resolved as accurately.

Data read-outs showing the TES relaxation time increasing with photon number

TES relaxation time increases with photon number. For N=4 photons the TES returns to the edge of the transition region in less than 10 μs. At N=47 it takes around 15 μs, and at a count of 1000 the relaxation time is approximately 50 μs. Image from NIST's page.

The group devised a model that fit the data extremely well for numbers between 100 and 1000, describing the results of 20,000 individual tests for each of several photon numbers. Another technique gave the correct values between zero and 30. The scientists were still working on a single model that combines the two.

What comes next

Gerrits said the scheme suits places where low light and high detection efficiency with low uncertainty are required, such as low-light-level homodyne detection for optical quantum states, which the team planned to develop. The photodiodes commonly used for homodyne measurements, he said, lack high detection efficiency and low noise in the telecom band. In a broader sense, a wider dynamic range for single-photon detectors advances a long-standing goal of more direct connections between radiometric standards that need high levels of light and single-photon metrology standards. Sae Woo Nam of PML described NIST's decade of work on photon-number-resolving detectors and the exploration of an operating region that could help link optical power measurements made by different devices at different power levels.

To reduce uncertainty further, the team looked at light sources that reliably produce an exact number of photons, rather than laser pulses. One candidate is parametric down conversion (PDC), in which a single photon passing through a nonlinear crystal becomes two photons whose combined energy and momentum equal the original. Alan Migdall of PML's Quantum Measurement Division explained that detecting one photon of a pair "heralds" its partner, guaranteeing that exactly one photon leaves the source. Running PDC to produce many pairs at once would give an N-photon source: if the TES counts the photons in the heralding channel, the number in the other channel is known exactly. That would give much lower uncertainty than lasers, and so a better light source for testing the TES itself.

Sources

Комментарии

Spinner Logo

Ещё на тему «Наука»

Автор: Hub Nexus editors
Top 10 in AI, week of 12 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 2 November 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 26 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 19 October 2026
CC0 1.0 (общественное достояние)
More than 70 percent of U.S. adults are overweight or have obesity, raising the risk of diabetes, heart and kidney disease and some cancers. What drives weight gain, and what helps.
CC0 1.0 (общественное достояние)
What Ohio gets from being mapped by laser