A clinical prediction model that fuses hospital measurements with chest X-rays should also know when it is unsure, so that unsure cases can go to a person. This paper, by L. Julian Lechuga Lopez, Tim G. J. Rudner and Farah E. Shamout, proposes a way to build that caution in through the model’s prior, and reports higher scores in tests on intensive care data. What follows summarizes the paper and its claims.

Overview of model training: a context dataset made from transformed clinical time series and X-ray images, and end-to-end training of the multimodal network

Overview of model training. Left: a multimodal context dataset is built by applying modality-specific transformations to clinical time series and chest X-ray images, producing a tailored distribution shift. Right: the multimodal neural network is trained end to end with the training set and the constructed context dataset. From the paper (Figure 1), CC BY 4.0.

The problem

Trustworthy machine learning in healthcare needs reliable uncertainty estimates, the authors say, because clinical practice is safety-critical. Uncertainty can come from model parameters, from noise and bias in the data, or from using a model on data unlike what it was built on. They argue that work on healthcare uncertainty has largely neglected tailored solutions, has mostly studied a single kind of input, especially medical images, and leaves multimodal clinical problems an unsolved challenge.

The idea

The authors use a stochastic (Bayesian) neural network trained with simple, scalable Gaussian mean-field variational inference. This method is known to underperform with standard, uninformative Gaussian priors, so they design what they call a multimodal data-driven (m2d2) prior over the network’s parameters. It places high probability on functions that are uncertain for inputs that differ meaningfully from the training data.

To do this they build a context set of artificial multimodal inputs meant to look different from the training data:

  • Clinical time series: three transformations, dropping the start, adding Gaussian noise and inverting the order of the series.
  • Chest X-rays: seven transformations meant to mimic real-world perturbations: random crop, random horizontal and vertical flip, Gaussian blur, random solarize, random invert and color jitter.

The model's uncertainty is meant to be higher on these shifted points.

The test

The authors combine clinical time series from MIMIC-IV with chest X-rays from MIMIC-CXR taken during the same intensive care unit stay, to classify acute care conditions, with 25 labels. They follow the preprocessing and the MedFuse architecture of earlier work: a two-layer LSTM for the time series, a ResNet-34 for the images and a fully connected layer to combine them. The training, validation and test sets held 7756, 877 and 2161 samples. They trained for 400 epochs with the Adam optimizer, a batch size of 16 and a learning rate of 2 × 10⁻⁴.

They report AUROC and AUPRC, plus “selective prediction” versions. In selective prediction, a model may decline to predict when its uncertainty exceeds a chosen tolerance, and those cases would go to an expert. The scores are averaged across rejection thresholds, so they reflect both accuracy and the quality of the uncertainty estimate.

Selective prediction: samples whose uncertainty is above the risk tolerance are sent to an expert, and the rest are predicted automatically

Selective prediction algorithm. For each input the model gives a prediction and an uncertainty estimate; if the uncertainty is higher than the chosen risk tolerance, the sample is sent to an expert for review and classification. From the paper (Figure 2), CC BY 4.0.

What they found

ModelAUROCAUPRCSelective AUROCSelective AUPRC
Deterministic0.7260.5030.7240.439
Bayesian, standard prior0.7290.5070.7480.448
Bayesian, m2d2 prior0.7350.5140.7480.452

Test-set results; higher is better. The paper also gives 95 percent confidence intervals, computed by bootstrapping.

The Bayesian network with the m2d2 prior scored higher than the deterministic model on all four measures, and above the Bayesian network with a standard prior on three; the two matched on selective AUROC. The authors also note that the selective AUPRC fell below the score with no rejection, which can happen when a model is poorly calibrated. They read the selective scores as showing the model’s ability to flag samples likely to be misclassified for a clinician to review.

Next steps

The authors plan to test the approach with missing modalities, on other tasks such as in-hospital mortality prediction, and on other multimodal datasets.

Sources

  • L. Julian Lechuga Lopez, Tim G. J. Rudner and Farah E. Shamout, “Informative Priors Improve the Reliability of Multimodal Clinical Data Classification,” arXiv:2312.00794, licensed under CC BY 4.0. Changed here: summarized and rewritten in hubnx's own words; the mathematics, appendices and references left out; figure captions shortened.

Комментарии

Spinner Logo

Ещё на тему «Наука»

Автор: Hub Nexus editors
Top 10 in AI, week of 19 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 12 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 2 November 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 26 October 2026
CC0 1.0 (общественное достояние)
Autism prevalence among 8-year-olds was 1 in 59 in 2014. The figure most often missed: 44% of the children identified had an IQ above 85. And while 85% had a developmental concern recorded by 36 months, only 42% had been comprehensively evaluated by then.
CC0 1.0 (общественное достояние)
More than 70 percent of U.S. adults are overweight or have obesity, raising the risk of diabetes, heart and kidney disease and some cancers. What drives weight gain, and what helps.