For years chip makers had a favorite way to count atomic-scale defects in transistors, and then they had to give it up because transistors got too small. NIST scientists, at the urging of industry, have now rebuilt the technique so it works on extremely thin transistor parts, and industry staff have already begun visiting NIST to learn it.

What charge pumping measures

Charge pumping reveals the relative number of atomic-scale defects such as broken bonds and missing atoms, which sharply reduce a transistor’s performance and reliability. They are called “interface traps” because they form where the semiconductor channel carrying the current meets the gate dielectric, a barrier that blocks charge from entering the channel unless the gate is on. A researcher in the Physical Measurement Laboratory’s (PML) Semiconductor and Dimensional Metrology Division said it was a favorite because it is inexpensive, easy to use and particularly suited to measuring these traps.

Diagram of a transistor showing where the signal enters and is collected in charge pumping and in the new frequency-modulated version

Where the signal enters and is collected, in both charge pumping and the new frequency-modulated charge pumping (FMCP). Image from NIST’s page.

In the traditional method a researcher applied a square-wave voltage to one transistor’s gate, alternately filling the traps with electrons and draining them, at frequencies from kilohertz to megahertz. Because the charge collected from the traps depends partly on the frequency, the measurement was repeated at several frequencies, and each signal was measured as direct current.

Why it stopped working

As transistors shrank, the gate dielectric got thinner, and thinner dielectric leaks more current to the semiconductor when the transistor is off. Traditional charge pumping picked up that leakage along with its own signal. At first researchers assumed the leakage was the same at any frequency, so they could subtract it afterward. Eventually the dielectrics became so thin and the leakage so large that the workaround failed. As the researcher put it, they were measuring a very small signal buried under a huge background. In a typical chip the charge pumping signal might be a thousand times smaller than the leakage current. According to the article, industry leaders abandoned the technique about a decade earlier.

The new version

Frequency-modulated charge pumping (FMCP) was created by NIST scientists with partners in academia and industry, and described in IEEE Transactions on Electron Devices in March 2015. It keeps the same basic idea of filling and draining traps, but applies one gate voltage waveform that is modulated back and forth between two or more frequencies hundreds of times per second. That turns the measurement into an alternating-current one, which pulls out a small signal far more precisely. Instead of several measurements analyzed offline, a single measurement gives the desired signal.

Comparison of traditional charge pumping and FMCP, in which one measurement gives the desired signal

Traditional charge pumping needed several measurements, each with overwhelming leakage noise, leaving a tiny difference between one and the next. FMCP measures the desired signal directly in one. Image from NIST’s page.

The researcher said it is easy and uses only equipment manufacturers already have, and that industry seems eager to have a form of charge pumping back.

A hidden error

While developing FMCP, the team found that leakage current actually changes slightly with the frequency of the gate voltage, which both the old and new methods had assumed it does not. An explanation in the article: no square wave is perfectly square, since it always takes time to rise and fall, and higher frequencies spend more of their time doing so. The error has only a small effect, so FMCP is still qualitatively useful for judging the density of interface defects. The team had proposed several workarounds and planned to keep studying the effect.

Sources

Комментарии

Spinner Logo

Ещё на тему «Наука»

Автор: Hub Nexus editors
Top 10 in AI, week of 2 November 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 26 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 19 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 12 October 2026
CC0 1.0 (общественное достояние)
From a Networking Event to a Seed Study: Tracking Eelgrass Flowers in Barnegat Bay
CC0 1.0 (общественное достояние)
Achromatopsia