Mercury is being phased out of thermometers because of safety concerns, but it is also built into the way thermometers are calibrated. The triple point of mercury, where its solid, liquid and gas phases coexist, is one of the 16 defined fixed points of the International Temperature Scale of 1990 (ITS-90), the international standard that runs from 0.65 K to approximately 1358 K. NIST scientists are studying substitutes, and one compound, sulfur hexafluoride (SF6), is showing strong promise.

Triple-point cells

Triple-point cells.

Why mercury is hard to give up

Reaching a triple point means cooling the material in a specialized cell, and the best mercury cells have uncertainties below 1 millikelvin (mK), which makes them excellent references. But concern over mercury's health and environmental hazards has led to strict regulation of its sale and distribution in the U.S. and abroad; the Mercury Export Ban Act of 2008, for instance, bars federal agencies from selling or distributing elemental mercury. Mercury thermometers have largely been replaced by comparably accurate alternatives, yet nothing readily replaces the mercury triple point as a reference between 210 K and 240 K. Fewer labs can keep a mercury cell, which could soon bottleneck thermometer calibration. NIST's Weston Tew of the Physical Measurement Laboratory said that every calibration below 0 °C relies on that point, so alternatives are imperative, and NIST can lead by testing the most promising materials.

The candidates

Researchers have two likely substitutes, carbon dioxide and SF6. Both are chemically inert, fairly inexpensive and have triple points just below mercury's, so they could be "drop-in" replacements with minimal adjustment to the temperature scale. Both need extensive testing to show they are practical. NIST is concentrating on SF6 and building the first SF6 triple-point cell made for temperature calibration.

SF6's triple point, about 233.555 K, brings challenges:

  • the cell must work at higher pressure than any other triple-point cell;
  • it would be the first fixed point made from a chemically synthesized compound, so very pure samples are harder to get;
  • matching mercury likely takes purity an order of magnitude better than what is usually sold, with impurities under one-millionth of the sample.

Results so far

Initial results from several SF6 cells are promising. With smaller cells and an ultra-high-purity gas, the researchers achieved a melting range of about 1 mK, the level needed to compare well with mercury. The larger immersion-type cells used in ITS-90 calibrations are harder, and preliminary data show melting ranges of a few millikelvin. Tew stresses that it is early work: once the chemical purity and equipment are good enough, what remains is improving technique. Further refinement of cell design and technique will decide whether SF6 can take over from mercury.

The source notes that most of the ITS-90 fixed points rest on phase changes at defined temperatures, which gives a fixed reference for calibrating standard platinum resistance thermometers. Others include the freezing point of aluminum and the triple point of water, which is used to define the kelvin.

Sources

Комментарии

Spinner Logo

Ещё на тему «Наука»

Автор: Hub Nexus editors
Top 10 in AI, week of 2 November 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 26 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 19 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 12 October 2026
CC0 1.0 (общественное достояние)
From a Networking Event to a Seed Study: Tracking Eelgrass Flowers in Barnegat Bay
CC0 1.0 (общественное достояние)
Achromatopsia