Автора пока нетВзять себе
- Лицензия
- CC0 1.0 (общественное достояние)По материалам pubs.usgs.gov
- Языки
- English
At Tinker Air Force Base near Midwest City, Oklahoma, activities contaminated the Garber-Wellington aquifer with volatile organic compounds, metals and other compounds to depths beyond 200 feet. In 2003–04 the USGS, with the Oklahoma Water Resources Board and the U.S. Air Force, dated groundwater above and below that layer to judge how vulnerable the base's drinking-water zone is.
The setting
Since the 1940s the base has housed strategic bombers and early-warning radar planes and served as a major aircraft repair facility. Discontinuous confining layers divide the aquifer in its first 200 feet. A 30-foot layer of shales and siltstones at about 200 feet, the LSZ-PZ confining layer, bottoms the shallow part and may be continuous beneath most or all of the base. Public-supply wells are in the "deep production zone" below it, where pressure heads are about 50 feet below those above the layer, which shows substantial potential for contaminated water to seep downward.
Three tracers
The apparent age of groundwater is the time since it last touched the atmosphere. Modern groundwater is generally more susceptible to contamination than old water, so age helps rate vulnerability.
- Tritium, a short-lived hydrogen isotope with a half-life of 12.32 years, was raised hundreds of times above background by weapons testing in the 1950s and early 1960s. Samples were taken in September 2003 from shallow and deep wells. Below 1 picocurie per liter was taken to mean water at least 50 years old; 1 or more meant modern water. Values ran from under 0.3 to 9.6.
- Helium-3/tritium dating uses the helium-3 that tritium decays into. Four wells thought to hold modern water were sampled in February 2004. Apparent ages were 13.4 to 35.7 years, with recharge dates from 1990 to 1968, consistent with modern recharge, though some samples looked like mixtures diluted with older water.
- Carbon-14, half-life 5,730 years, was sampled in March 2004 from 11 wells thought to hold older water. Concentrations were 52 to 93 percent modern carbon. Because chemical reactions dilute carbon-14 and make water look older, modelling adjusted the ages to between modern and 3,000 years, with uncertainty.
What it means
The report cautions that all three methods have measurement errors and ages are not absolute, since a well's water may mix sources of different ages. The tracers disagreed in places: Well 1-50CR had tritium of 7.2 picocuries per liter, implying some modern water, and a helium-3/tritium date of March 1982, yet a modelled carbon-14 age in the thousands of years.
Sources
- U.S. Geological Survey fact sheet, https://pubs.usgs.gov/publication/fs20053099; rewritten in hubnx's own words.