Автора пока нетВзять себе
- Лицензия
- CC0 1.0 (общественное достояние)По материалам pubs.er.usgs.gov
- Языки
- English
The U.S. Geological Survey (USGS) has sent groundwater samples from the Idaho National Laboratory (INL) to its lab for volatile organic compound (VOC) tests without adding acid, even though the lab later suggested acidifying them. A 2020 study compared paired preserved and unpreserved samples to see whether the two differ. Unpreserved samples showed no consistent bias toward higher or lower concentrations.
Why the question mattered
The INL covers about 890 square miles of the eastern Snake River Plain in southeastern Idaho and is run by the Department of Energy (DOE). Its waste disposal has put some waste constituents into the aquifer below. The USGS INL Project Office, working with DOE, provides an independent assessment of how those constituents occur, move and change. VOCs reached the aquifer through wastewater injected at Test Area North and at the Idaho Nuclear Technology and Engineering Center, through discharge to infiltration ponds at the Advanced Test Reactor Complex, and from an estimated 88,400 gallons of organic waste buried before 1970 at the Radioactive Waste Management Complex (RWMC). Background VOC concentrations in the aquifer there are generally below 2 micrograms per liter.

Location of the INL, its facilities and the wells sampled in 2020 (USGS).
The history of the method matters. In the late 1980s and early 1990s the USGS National Water Quality Laboratory (NWQL) wanted raw, unfiltered, chilled water. In the mid-to-late 1990s it suggested adding hydrochloric acid (HCl) in the field, a change the USGS had already tested and found made no statistically significant difference to VOC results across groundwater, surface water, stormwater runoff and sewage effluent. The laboratory kept accepting raw samples, though, and the INL kept sending them to stay consistent with its older data. Now it was considering adding acid.
How the test worked
Samples came from 25 wells in the aquifer and one in perched groundwater above it, covering many depths, places and seasons. At each well, two samples were taken one after the other. The first was only chilled and is called unpreserved. The second was acidified with about five drops of HCl, enough to reach a pH of 2, and chilled, and is called preserved. Both went into 40-milliliter amber vials filled to overflowing and capped without headspace, were kept at 4 degrees Celsius, plus or minus 2, and went by overnight mail to the NWQL, usually within five days. The laboratory measured 61 VOCs.
What the results showed
Eleven VOCs were found above the reporting limit in at least one well. Most detections came from wells at or near the RWMC: carbon tetrachloride rose above the federal drinking-water limit in the RWMC production well and in well USGS 92 (perched water), and trichloroethene did so in USGS 92 and GIN-2.
Neither method gave consistently higher results. In well GIN-2, all four VOCs above the reporting limit were higher in the unpreserved samples. In well M3S at the RWMC, five VOCs were lower in the unpreserved samples.
| Test | Result |
|---|---|
| Relative percent difference (usual criterion: 20 percent or less) | Acceptable reproducibility for every VOC above the reporting limit |
| Normalized absolute difference (which allows for lab uncertainty) | About 81 percent of samples statistically equivalent |
| Rank-sum test on five VOCs found in more than six pairs | No statistical difference, with p-values from 0.2033 to 0.3254 |
| Linear regression of unpreserved against preserved | R-squared of 0.9992 |

A regression of VOC concentrations in the paired samples, for values above the reporting limits (USGS).
Quality-control samples from 1996 through 2018 showed no bias from field equipment, preservation or handling. The 2020 quality-control samples were not tested for VOCs, and the study did not test lab-spiked samples.
What it means
The USGS concludes that the preservation method does not make a measurable difference to VOC concentrations. Any slight variability should not compromise comparisons between historical and current data, or long-term geochemical evaluations, so the monitoring network's results stay comparable across past, present and future sampling.
Sources
- U.S. Geological Survey, Evaluation of sample preservation methods for analysis of selected volatile organic compounds in groundwater at the Idaho National Laboratory; rewritten in hubnx's own words.