Автора пока нетВзять себе
- Лицензия
- CC0 1.0 (общественное достояние)По материалам pubs.usgs.gov
- Языки
- English
When a geochemical sample sent to the U.S. Geological Survey (USGS) laboratory might end up in court, it got a fourth index card that anyone taking custody of the sample had to sign. That is one of the rules in a 1997 USGS circular on how the Mineral Resource Survey Program (MRSP), formerly the Branch of Geochemistry, handles routine and evidentiary samples. The rules were drawn up by a team from the program’s Analytical Chemistry Services Group, which consulted law enforcement agencies, laboratories that work with special samples and the Interior Department’s Solicitor General.
Routine samples
Every sample comes with a completed request for analysis (RFA) form, which stays with the sample as its accountable record and notes anything unusual, such as an evidentiary sample or a high element concentration.
- Sample control scans samples for radioactivity. Above the safe levels set by the program’s safety officer, they go to alternate storage, and if the officer rejects them the submitter must retrieve them within 30 days.
- Samples are counted against the RFA, discrepancies are settled, and they go on numbered shelves.
- The RFA is entered in a computer, which issues a job number for each batch and a laboratory number for each sample.
- Three 3-by-5 cards are typed. One tracks the job, one is filed by submitter name to record when each analysis finishes, and one is a permanent storage cross-reference.
- Six months after analysis ends, the samples move to permanent storage.

Figure 2 from the USGS circular: self-adhesive labels.
When a sample might be evidence
Before such samples arrive, the project leader meets with representatives of sample control, the computer group, the preparation and analytical laboratories and quality assurance to settle the number of samples, dates, preparation, methods, hazards and cost. The pre-assessment form must be signed by the chief scientist before the samples are accepted.
Then:
- Custody. A designated sample control custodian keeps the samples, forms and tracking cards in a locked evidentiary area. Entry is by key card, monitored by the Federal Protective Service, and anyone else who enters signs a visitors log.
- Acceptance. The custodian can refuse a sample that is poorly sealed, damaged, leaking, too toxic or radioactive, or arrives with incomplete paperwork. The submitter and the receiver both sign a chain-of-custody form kept in a bound book.
- Withdrawal. An analyst contacts the custodian, signs the visitors log, checks the evidence seals, and signs the tracking card and the form with name, date, time, reason, amount and destination. Samples are never left unattended or unsecured and go back as soon as the needed amount has been weighed.
- In the lab. While evidentiary samples are in a laboratory, no other samples are allowed in it, to rule out cross-contamination. Lab books are bound and written in permanent ink, and anyone entering signs a log.
![]()
Figure 3 from the USGS circular: the 3-by-5 sample control card.
Special cases
For neutron activation analysis, samples go to a controlled-access building at the Denver Federal Center, are heat-sealed in polyethylene vials, and spend the night in a reactor. They then wait 5 or 6 days in a locked, lead-shielded container before analysis, and the analyst signs the forms the Nuclear Regulatory Commission requires. Data from the analysis are copied to a floppy disk locked in a cabinet.
When excess sample is returned to the submitter, a 3-ounce unaltered split is kept in the locked area until litigation ends. Samples with short viability, such as water samples, are held for 6 weeks and then returned with their documents. Submitters are contacted every year about the status of the case, and storage charges may apply after two years. Information about the samples goes only to the submitter; other requests go to the Solicitor General.
The people and the security
The supervisory sample control specialist is the principal custodian, with a designated backup. Staff who work on evidentiary samples are certified by the laboratory chief, have a compliance element in their work plans and are bound by the Ethics Reform Act of 1989. Training records show which analysts are qualified for each procedure. In court, the chief scientist or the laboratory manager represents the lab when routine procedures were used, and the research scientist must provide documentation and testimony when nonroutine methods were used.
The circular describes three layers of security: a fenced entrance with guards at the Denver Federal Center, regular patrols by the Federal Protective Service, and the building’s own card readers, motion detectors and locks on the sample control, preparation and laboratory areas.
Sources
- U.S. Geological Survey, Chain of custody; recommendations for acceptance and analysis of evidentiary geochemical samples, U.S. Geological Survey Circular 1138, U.S. Government Printing Office, 1997; rewritten in hubnx’s own words.