Автора пока нетВзять себе
- Лицензия
- CC0 1.0 (общественное достояние)По материалам www.nist.gov
- Языки
- English
- Темы
- Наука
Experiments on lithium had disagreed with theory for years, by as much as 16 standard deviations, even though theory makes extremely accurate predictions about the differences in the light emitted by the two stable lithium isotopes. Researchers in NIST's Physical Measurement Laboratory (PML) traced the trouble to something earlier experiments had overlooked: the polarization of the laser light used to measure the lines.
The disagreement

The investigators took high-precision measurements of the D1 and D2 transition lines in the two stable isotopes of lithium. Image from NIST's page.
Craig Sansonetti, who led the work, described the earlier data as "all over the place": the range of differences was as large as the signal being measured, and the experiments did not even agree on its sign.
It mattered because theorists have proposed using differences in the emissions to probe how the charge radius of the lithium nucleus differs between isotopes. Lithium is the most complex atom whose structure can be calculated from first principles accurately enough to be sensitive to that effect, which makes it a benchmark for testing theory.
Lithium also has an isotope, 11Li, with a half-life of 8.75 ms, whose nucleus is a "halo": some of its neutrons are so loosely bound that they are quasi-independent. No conventional scattering measurement of its nuclear size exists, so the isotope shift method is an attractive alternative. Before trusting it for 11Li, the team wanted theory confirmed on the stable isotopes, where independent scattering measurements of nuclear size are available.
The measurement
The team used a laser to excite a collimated beam holding both 6Li and 7Li atoms and watched for the light given off at two atomic transitions, the D1 and D2 lines. Each line falls at a slightly different frequency for the two isotopes, and the team measured that shift, calibrating against a high-precision frequency comb tied to a cesium clock.
| Line | What the data looked like | Fit to theory |
|---|---|---|
| D1 | Signals clearly and sharply resolved | Near-perfect |
| D2 | Much of the data poorly resolved | Not accurately modeled |
Sansonetti's explanation of the D2 problem was that most D2 lines are unresolved blends of three hyperfine components whose spacing is smaller than the natural width of the line, about 5.87 MHz, so quantum interference among them was presumably distorting the result.
What the polarization did
After a good deal of trial and error, the team varied the polarization of the incoming laser light with a wave plate. The observed line profile changed shape, something no earlier experiment had considered, and the apparent position of the D2 transitions shifted by as much as 50 times the experimental accuracy. Interference between the hyperfine components was smallest at slightly over 50 degrees from vertical.
To understand why, Sansonetti asked colleagues in the laser cooling and trapping group, where Trey Porto had a program that needed only minor changes to calculate the effect. That same afternoon it produced qualitatively what the lab had seen.

The second panel from the right shows that a polarization of 51 degrees from vertical gives data that fit the prediction far better. Black lines are the signal calculated by theory and red dots are experimental data; the bottom row shows how far the data differ from theory in each case. Image from NIST's page.
With polarization accounted for, the data fit theory well and agreed with the latest and presumably best predictions. Earlier work used optical interferometry; measuring by frequency gained nearly two orders of magnitude in accuracy, which Sansonetti called essential to the experiment's success.
Sources
- National Institute of Standards and Technology, Reading Between the Lines in Lithium: New measurements of unprecedented accuracy resolve a longstanding data disagreement; rewritten in hubnx's own words. The article cites the July 2011 Physical Review Letters paper by C. J. Sansonetti, C. E. Simien, J. D. Gillaspy, J. N. Tan, S. M. Brewer, R. C. Brown, S. Wu and J. V. Porto.
Комментарии