Автора пока нетВзять себе
- Лицензия
- CC0 1.0 (общественное достояние)По материалам pubs.usgs.gov
- Языки
- English

The three survey areas (North, Well 72 and Nose) north of Sioux Falls, South Dakota. Image from the USGS report.
Sioux Falls, South Dakota, wanted to know where to put new municipal supply wells, so it asked the U.S. Geological Survey (USGS) to image the subsurface without drilling additional borings. The USGS used electrical resistivity surveys, a non-invasive and cost-effective approach, on three parcels north of the city. The surveys mapped the top of the glacial till and the thickness of the Big Sioux aquifer.
Why the surveys
City staff had picked parcels that might hold new wells if they could be acquired and lay within the aquifer. Managers also needed the depth to water, the aquifer's makeup and thickness, and the direction of groundwater flow. In 2021 and 2022 the city began on one parcel just south of Interstate 90, the Nose area, by drilling test borings and temporary monitoring wells. Surveys there in March 2022 filled in the ground between them. Their usefulness led to two more in November 2025: the North area, east of the Big Sioux River between 256th and 257th streets, and the Well 72 area, near municipal supply well 72 between 257th and 258th streets.
Four layers
The area's geology has four layers:
- Surficial deposits: topsoil, organic material, silt and clay.
- The Big Sioux aquifer, glacial outwash of silts, sands and gravels. It averages about 34 feet thick, with an estimated maximum of 96 feet between Sioux Falls and Dell Rapids.
- Glacial till, a dense clay with interbedded silt, sand and gravel, up to 120 feet thick.
- Sioux Quartzite, the oldest layer, beneath the till (or beneath the aquifer where there is no till).
How resistivity surveying works
Steel stakes along a cable act as electrodes. A meter sends current into the ground through two of them and measures the resulting voltage at others, and software turns the readings into a two-dimensional cross section of how strongly the ground resists current. Wider electrode spacing sees deeper but with less detail. The USGS surveyed 22 transects, 3.4 line-kilometers in all, with 56 electrodes per line spaced 3 m apart (4 m was tried once), and used a dipole-dipole array. Precise positions and elevations of each electrode were surveyed with real-time kinematic GPS.

A resistivity cross section of one transect, with each geologic unit labeled. Image from the USGS report.
In the models, soil showed as low resistivity (below 30 ohm-meters) in a layer 2 to 3 m thick. The aquifer's sand and gravel showed as high resistivity (above 60 ohm-meters) below it, and the till as a thick, low-resistivity layer (typically below 40 ohm-meters) below that. In the North area a fourth, high-resistivity layer likely represents the Sioux Quartzite. The team picked each aquifer-till contact by hand and checked it against nearby borings and crossing transects. Contours more than 20 m from a transect are inferred, and models are most accurate near the center of a line.
What the maps show
| Area | Top of glacial till | Aquifer thickness | Average thickness | Trend |
|---|---|---|---|---|
| North | 1,403 to 1,418 ft | 23 to 38 ft | about 30 ft | Till slopes down from east to west toward a slough, so the aquifer thickens that way; east-west channels could steer groundwater |
| Well 72 | 1,400 to 1,409 ft | 28 to 40 ft | about 32 ft | Till slopes down from northwest to southeast toward well 72; a low channel crosses the middle of the transects |
| Nose | 1,362 to 1,395 ft | 33 to 70 ft | about 50 ft | Till slopes down westward toward the river; thickest, 65 to 70 ft, along transect L1 near boring SF23 |

Contours of aquifer thickness in the North area. Image from the USGS report.

Contours of aquifer thickness in the Well 72 area. Image from the USGS report.
Against borings, the surveys held up in most places. In the Nose area the difference was under 3 feet on most transects, with a maximum of about 10 feet. At Well 72 the till depth from the models differed from eight borings by 0.68 to 11.80 feet, about 4.1 feet on average, growing with distance from the line. The report notes that till depth can change a lot over short distances, so the gap may be real. If groundwater follows the top of the till, it would move along those channels.
Sources
- U.S. Geological Survey, Scientific Investigations Report, Big Sioux aquifer resistivity surveys near Sioux Falls, South Dakota, https://pubs.usgs.gov/publication/sir20265023/full; the imported title was cut off, so this page's title is hubnx's own; rewritten in hubnx's own words.