Eastern Dade County, Florida, has 16 coastal hydraulic control structures, and water managers needed to know how much freshwater passes through them. A USGS study with the South Florida Water Management District built new discharge ratings for all 16, using acoustic Doppler instruments that can measure quickly while gates are moving. The work is part of the USGS South Florida Ecosystem Program, started in fiscal year 1995 to gather hydrologic, cartographic and geologic data on mainland south Florida, Florida Bay and the Keys and reef ecosystems, as a contribution to the intergovernmental restoration effort.
Why the discharge matters
Discharge data are needed to quantify water that could go to water supply and ecosystem restoration, and to calibrate regional hydrologic models. The volume leaving through these structures is of great interest because it affects both the freshwater available for people and the ecology of Biscayne Bay, which receives it. The sheet says it makes up the majority of freshwater flow into the bay, since other structures farther north discharge into the Intracoastal Waterway.

Types of coastal hydraulic control structures. Image from the USGS fact sheet.
How it was measured
In the field, crews used Acoustic Doppler Current Profilers (ADCPs) mounted on boat bows and facing the flow. At one site, one boat sat directly upstream of the structure and another around the bend. Tag lines strung across the canals let each boat be pulled slowly across the water, and stages were noted at the start and end of each measurement. The nearby gagehouse holds upstream and downstream stage recorders and the gate controls.

Field setup for an Acoustic Doppler Current Profiler. Image from the USGS fact sheet.
When gate openings were planned for a day, measurements were repeated at each opening. The ADCPs worked quickly enough to keep up with fairly rapid gate changes. Water-level, gate-opening and discharge data were combined in a spreadsheet, flow regimes were identified, and a least-squares fit gave the best coefficients for each rating.
Results
The new computed ratings were compared with the existing theoretical ones for all 16 structures. The difference varied from structure to structure. Only 12 structures had the remote telemetry needed to compute continuous discharge; the other four were considered minor or, in one case, discharged well south of the area of interest. For 1994 the total freshwater flow from the 12 came out differently under the two sets of ratings, and negative flows were left out because flow to the bay is the focus.
The sheet concludes that the speed of ADCP measurement was essential in rapidly changing conditions, that a wide enough range of conditions was measured to make useful ratings for every structure, and that the ratings will let managers be substantially more accurate about flows to the east coast. The techniques are to be applied next to structures in Broward and Palm Beach Counties.
The full fact sheet is embedded below.
Sources
- U.S. Geological Survey fact sheet "South Florida Ecosystem Program: Quantifying freshwater discharge for coastal hydraulic control structures in eastern Dade County, Florida"; the location map is left out; the stored text is scanned and partly garbled, so its flow totals are left out: https://pubs.usgs.gov/publication/fs12396; rewritten in hubnx's own words.