In April 2004 USGS divers installed an acoustic Doppler velocity (ADV) meter in the opening of Main Spring at Barton Springs in Austin, Texas. Such meters use sound waves to measure water velocity in up to three directions, and this one gives a way to estimate springflow on days when the usual method fails.
The usual record
The USGS, in cooperation with the City of Austin, has published daily mean springflow for station 08155500 Barton Springs at Austin since March 1, 1978, the longest continuous water-quantity record for the springs. The station's flow is the combined flow of Eliza, Old Mill and Main Springs; Upper Barton Spring is not included. Daily flow is computed from gage height, read every 15 minutes at a monitoring well about 100 feet south of Main Spring, through an empirically developed stage-discharge relation. As of 2005 a data collection platform sent readings by satellite at 4-hour intervals.
The relation is checked by periodic manual measurements: the discharge of Barton Creek below the pool's downstream dam and of Old Mill Spring are added, and the creek's discharge upstream from the pool is subtracted. About 200 such measurements since 1958 built the relation for normal, pool-full levels.
An accurate record matters. The springs are the only known habitat of the Barton Springs salamander, a federally listed endangered species that depends on reliable springflow, and sustainable Edwards aquifer yields cannot be set without an accurate record. The 3-acre swimming pool they feed is also a popular attraction.
Why the usual method fails
Most springflow emerges from the pool, so the pool's water level strongly affects computed flow. Pool staff change levels on purpose, and storms push water through. The definition of "pool-full" is ambiguous and has changed with pool operation. Stormflow usually raises the pool by several feet, sometimes more than 10 feet briefly, and the pool is drawn down for cleaning and maintenance for hours or days. When levels are far from normal the stage-discharge relation does not apply, and periodic measurement will always be necessary.
What velocity adds
In September 2003, during a major pool drawdown, USGS divers measured water in the Main Spring orifice flowing about 40 percent faster than normal, as expected with less water depth over the opening. That pointed to a complementary method: use velocity as an index of springflow when the stage-discharge relation does not apply.
The ADV meter, mounted on the orifice's ceiling on April 1, 2004, has a cable that surfaces under a lifeguard tower and connects to the station's platform. Every 4 hours it sends sixteen 15-minute values of velocity in three directions and of signal strength, each averaged over 5 minutes. The report uses the component along the main flow, measured about 8 feet inside the orifice. A ratio of discharge to index velocity needs extra flow measurements during and just after unusual pool levels.
What the first period showed
From April 1 to September 30, 2004 (183 days), Barton Springs discharged more than 8.8 billion gallons. Seven periods, totalling 21 days, had pool conditions where the stage-discharge relation was not applicable, so daily flow for those days has to be estimated.
Sources
- U.S. Geological Survey fact sheet, https://pubs.usgs.gov/publication/fs20053044; rewritten in hubnx's own words.