Автора пока нетВзять себе
- Лицензия
- CC0 1.0 (общественное достояние)По материалам www.epa.gov
- Языки
- English
Many sprinklers are installed where the system's water pressure is higher than the nozzle is meant to handle. EPA says that causes excessive flow, misting, fogging and uneven coverage, and wastes water. Outdoor use is about 30 percent of average household water use nationwide, and more in hotter, drier places; EPA's current estimate is nearly 8 billion gallons a day for residential outdoor use, mainly landscape irrigation. Experts estimate that as much as 50 percent of outdoor water use is wasted by overwatering from inefficient methods and systems.
What a pressure-regulating body does
The sprinkler body is the outer shell that connects to the irrigation pipes and holds the spray nozzle. Some models regulate pressure at the nozzle's inlet. WaterSense labeled spray sprinkler bodies have integral pressure regulation, which gives a constant flow at the nozzle and cuts excess flow when system pressure is high. Because the body keeps pressure near the nozzle's optimum, the nozzle produces the right spray and coverage for more even watering across the landscape.
What it could save
| Measure | EPA's estimate |
|---|---|
| An average household using 50,500 gallons outdoors, operating at or above 60 pounds per square inch | Nearly 5,600 gallons and $60 a year in water and sewer costs |
| Every home with an automatic system running above optimal pressure | More than 31 billion gallons a year nationally |
How the label came about
EPA waited several years to write a specification, until industry reached a consensus standard it could cite for performance and testing, ASABE/ICC 802. It then worked with several laboratories to check that the test method could be repeated and reproduced, which exposed inconsistencies that were fixed, and tested products on the market to set the thresholds.
Labeled bodies are independently certified on two requirements:
- Flow rate at various pressures: how much the flow rate varies at different pressures, and that it stays consistent at pressures above the manufacturer's regulation pressure.
- Outlet flow rate: that the pressure drop across the body does not become so large that it hurts performance.
EPA released the final specification on September 21, 2017. It had also issued a draft specification for spray sprinkler nozzles, which attach to the bodies, to earn the label.
Sources
- U.S. Environmental Protection Agency, Spray Sprinkler Bodies, WaterSense; rewritten in hubnx's own words.