This 3-D printer moves away from solid material deposition and prints liquid inks, with the aim of making ultrathin film coatings or layered objects. A syringe pump attachment does the pushing, and Franklin, the control software, runs on a Raspberry Pi connected to the printer, a Prusa. The printer should never need to be turned off.

Printer in home position (Photo: Ampringl on Appropedia, CC BY-SA 3.0).
Six steps
- Start up. Open the Franklin terminal on the Raspberry Pi, or on a laptop connected to it. The printer sits in its standby (home) position with no syringe.
- Level the bed. Adjust the screws at the four corners until the bed is level at the center of the print area. Then check with a level that the syringe pump platform is level from -x to x, keeping the air bubble in the middle. If the rods are not parallel with the bed, the print will be uneven.
- Load the printer. Secure the syringe in the pump with the white printed holders, then adjust the carriage, the part that pushes down on the syringe, by changing the extruder value in Franklin: a negative value moves it up, a positive value moves it down. Place the blue printed holder on top of the syringe. Move the head to a convenient position for loading ink (the guide’s author likes 25 on each of x, y and z) and set the ink container on the bed under the tip. Lower the tip into the ink, and set a negative extruder value, which would retract filament on an ordinary printer, to draw ink into the syringe. Raise the syringe, take away and stopper the ink vial, and put a test slide on the bed.
- Calibrate. Lower the syringe in Franklin until the position z reads 0 without hitting the bed, then copy those values to the target z. Repeat as needed, then adjust the target z until the tip is just above the glass slide; 0.4 mm is a good value but depends on the application. Physically lower the syringe if the numbers require it. Then move the head across the print area, from -25x to 25x, and check that the gap between tip and slide stays the same. Repeat in the perpendicular direction.
- Print. Warm the heated bed to the test parameters. Push a little ink out to one side to prime the syringe head, which is essential for fluid to land as intended. Set a park position for Franklin to print from, adding 20 mm to the z value of the home position; the head will crash if the target z is above the park z. With the G-code loaded and adjusted (in this case a 45 degree angle was added to correct for internal geometries), press the print selected button.
- Set to idle. Switch off the heated bed and unload the ink as in step 3, using a positive value rather than a negative one. Remove and safely store the syringe, then click home and the printer idles.

Fig. 3a: level on the print bed surface (Photo: Ampringl on Appropedia, CC BY-SA 3.0).

Fig. 3b: level on the cross bars (Photo: Ampringl on Appropedia, CC BY-SA 3.0).

Fig. 4: loading the syringe (Photo: Ampringl on Appropedia, CC BY-SA 3.0).

Fig. 7c: syringe tip in ink solution (Photo: Ampringl on Appropedia, CC BY-SA 3.0).

Fig. 9b: syringe zeroed 0.3 mm above the surface (Photo: Ampringl on Appropedia, CC BY-SA 3.0).

Fig. 10: checking z-direction zero height (Photo: Ampringl on Appropedia, CC BY-SA 3.0).

Fig. 12: ready to print conditions (Photo: Ampringl on Appropedia, CC BY-SA 3.0).
Troubleshooting
If the rods are uneven, a coupling has usually come loose. Tighten it and level the x-direction rods again. The page says designs will be added after a paper is submitted.
Sources
- Appropedia, Open source syringe pump 3-D printer, by its contributors, under CC BY-SA 4.0. Changed here: rewritten in hubnx's own words and condensed, with the project databox, links, notices and some photographs and screenshots left out; photographs kept carry their own credits and licences (Ampringl on Appropedia, CC BY-SA 3.0). This version stays under CC BY-SA 4.0.