Автора пока нетВзять себе
- Лицензия
- CC BY-SA 4.0По материалам www.appropedia.org
- Языки
- English
The Sunlight Power Box is a low-cost solar energy storage system built from lithium-ion cells salvaged from discarded laptop battery packs. A pack of twelve screened 18650 cells, arranged 3S4P, stores about 111 Wh at a nominal 11.1 V, charges from a 100 W solar panel, and runs LED lighting, phone charging and a small communications router. The designer, Hajoon Kim, aims it at households and small facilities in off-grid or unreliably supplied areas, to be built and repaired by non-specialists using hand tools and a multimeter. The page is candid about what is proven: its numbers come from models, not long-term measurement.

B6 balance charger testing an 11.1 V 3S pack. Photo: Kimh60057 on Appropedia, CC BY-SA 4.0.
How much to trust the numbers
The screening yield, balancing, cost, carbon-saving and solar-balance figures on the page are model-based, produced from Monte Carlo and parameter models using values from published literature, and have not been checked against a long-term dataset. A physical prototype with 3S/4S battery management boards, a B6 balance charger and an 11.1 V pack was built and tested and showed the configuration is workable, but it is not where the numbers come from. The author advises treating them as design guidance and measuring your own cells.
Who it is for, and what it can do
It suits people who can get discarded laptop packs, own a multimeter and will test every cell individually. It is not a beginner project: salvaged lithium cells can vent or catch fire if mishandled. The box can run LED lighting through the evening, charge phones daily and power a small router. It cannot run a fridge, iron, TV, pump or anything on mains AC; the output is 12 V DC and 5 V USB only.
The safety rules
The page lists these as non-negotiable:
- An adult must be present when opening packs, wiring and on the first charge.
- Never use water on a lithium fire. Keep a bucket of dry sand within reach; if a cell smokes, move away, cover it with sand and move it outdoors with a long tool.
- Never bridge the positive and negative terminals, and never solder directly onto a cell, because sustained heat can damage it and cause a failure days later. The design uses a screw-terminal holder to avoid soldering.
- Never build without both the battery management system (BMS) and the fuse.
- Stop if anything is hot, wear eye protection, gloves and closed shoes, and keep small children away.
- Discard any cell that is dented, crushed, corroded, leaking, swollen, burnt, damp or smelling of solvent, and any cell that reads below 2.5 V. Rejected cells go in a metal container with sand and then to an e-waste facility.
Why the BMS is not optional
In the author's model of three cells starting 0.35 V apart, over 40 cycles an unbalanced pack's voltage spread grew to 590 mV and the highest cell passed 4.2 V, reaching overcharge and thermal-runaway conditions, while active and passive balancing both converged. With salvaged cells of mixed histories, the author calls the BMS the safety system, not an accessory.
Screening cells
Screening decides both safety and pack life, and it is the step the author says most hobby builds skip. In the field method, check voltage with a multimeter, then run each cell through a four-bay tester-charger, which takes several hours, and accept only cells at 2200 mAh or more; twelve are needed, plus two or three spares. With an internal-resistance meter, cells can be graded:
| Grade | Internal resistance | Capacity | Use |
|---|---|---|---|
| A | under 50 mΩ | 2200 mAh or more | Main pack |
| B | under 80 mΩ | 1800 mAh or more | Auxiliary or low-load use |
| Discard | above these limits | below these limits | Recycle, do not reuse |
The model estimates that about 86% of cells from packs at 70% mean state of health would be reusable. Accepted cells are sorted into three parallel groups of four whose capacities are within about 100 mAh, and joined only when all sit in a narrow voltage band, since cells at different charge levels cause large equalising currents.
Build and wiring
The pack is 3S4P (extendable to 3S8P): 11.1 V nominal, 12.6 V full charge (4.2 V a cell), 9.0 V cut-off. Parts include a 3S BMS, a 3×4 screw-terminal holder, an MPPT solar charge controller with a lithium mode, a 100 W panel, a 20 A fuse, a main switch, a 5 V USB plate and 12 V LED lighting. The author's full kit, including tools and protective equipment, cost roughly 1.52 million KRW (about US$1,130); the cells were free.

3S/4S battery management board. Photo: Kimh60057 on Appropedia, CC BY-SA 4.0.
The page calls the charge controller setting the most common way to make the system dangerous. Lead-acid profiles push 14.4 V, which overcharges lithium cells and can cause a fire, so the controller must be in lithium / Li-ion / 3S mode and stop at 12.6 V; if that cannot be confirmed, do not use it. Connect the battery first, then the panel (with it covered or in the evening, since a panel in sunlight is live), and the loads last. Protection has three layers: the BMS, whose balance leads must be metered in order from the negative end before the plug goes in (about 3.7 V, 7.4 V and 11.1 V); a 20 A fuse on the positive line; and a main switch everyone in the home should know.

Balance lead wiring. Photo: Kimh60057 on Appropedia, CC BY-SA 4.0.
What the model says about energy and cost
| Modelled result | Value |
|---|---|
| Daily generation, 100 W panel, 5 peak sun hours, 0.75 loss factor | 375 Wh |
| Daily use (lighting, phone charging, router) | 150 Wh |
| Surplus | 225 Wh a day |
| Autonomy from full charge with no sun | about 1.5 days |
| Levelized cost of storage, recycled 18650 pack | 0.222 USD/kWh |
| Levelized cost of storage, new lithium-ion | 0.288 USD/kWh |
| Levelized cost of storage, lead-acid with desulfator | 0.300 USD/kWh |
The costs are calculated over 20 years at 300 cycles a year. The recycled pack is cheapest despite a shorter cycle life, because its upfront cost is so low. For manufacturing carbon, the model gives about 35.5 kg of CO₂ for 48 new cells against 3.6 kg for recycled ones.
Care and limits
Weekly, check for warmth, insects or water and meter the pack; monthly, clean the panel, tug-test wires, tighten screws and inspect cells for swelling. If a cell fails, switch off, unscrew the plate, put the cell in the sand container and fit a tested spare. Keep the box indoors, shaded, ventilated and away from children, flooding and cooking fires.
The author lists the limits: results are modelled; long-term cycle testing and a field pilot have not been done; recycled cells have a shorter cycle life; and the system is DC only. A picture-based build manual and a free offline simulator (English, Korean, Bahasa Indonesia and Filipino) accompany the design, and the author asks anyone who builds it to share measured data.
Sources
- "Sunlight Power Box," Appropedia, by its contributors, licensed under CC BY-SA 4.0 (https://www.appropedia.org/Sunlight_Power_Box); designed and documented by Hajoon Kim. Photos by Kimh60057 on Appropedia, CC BY-SA 4.0. Changed here: rewritten and condensed in hubnx's own words; the project box, notices and edit links left out.
Комментарии

Читать дальше
Ещё на тему «Природа»