Автора пока нетВзять себе
- Лицензия
- CC0 1.0 (общественное достояние)По материалам pubs.usgs.gov
- Языки
- English
Two turbidity sensors can read the same water differently, and when a river monitor is replaced, a sediment model built on the old one can quietly go wrong. This USGS report tells how the agency handled that at seven Indiana supergages.
Supergages and why turbidity matters
A supergage is a USGS streamgage that adds continuous and sampled water-quality measurements to its streamflow data, so real-time concentrations and loads can be reported. Indiana uses them to track sediment and phosphorus, which help decision-makers see how land use and management affect recreation, ecology and the condition of rivers. Partners include the Iroquois River Conservancy District. The data flow to the USGS National Water Information System and its National Real-Time Water-Quality network. Six of the sites are in the Kankakee River Basin in northwestern Indiana and one, on Eagle Creek, is in central Indiana.
At each site a monitor records water temperature, dissolved oxygen, specific conductance, pH and turbidity every 15 minutes. Turbidity, the cloudiness of the water, serves as a surrogate. Earlier reports used it to compute suspended sediment and total phosphorus concentrations and loads from discrete samples.
The problem
YSI Inc. model 6136 monitors were first put in Indiana in 2010. Starting in November 2018 they were replaced by newer EXO multiparameter monitors because the older series was going out of production. The two measure turbidity by the same method, but their sensors give different values, and the published surrogate models were built on the older readings.
The comparison
From November 2018 to December 2021, the two monitors ran side by side at the seven sites, depending on the availability of approved data for each. Ordinary least squares regression gave site-specific conversion factors so that EXO readings can be corrected for use in the existing models. On average, linear regression explained 98 percent of the variation between the two sensors.
The result
The conversion factors let the USGS keep computing near-real-time suspended sediment and total phosphorus concentrations and loads for the national network without rebuilding the models. The factors themselves, one set per site, are in the report’s tables.
Sources
- U.S. Geological Survey, Scientific Investigations Report, “Comparison of turbidity sensors at U.S. Geological Survey supergages in Indiana from November 2018 to December 2021” (https://pubs.usgs.gov/publication/sir20235077/full); the stored maps, equations and tables are not reproduced; rewritten in hubnx’s own words.
Комментарии