A nuclear waste container can be as long as a full-size car and weigh ten times as much, and it has to be weighed very accurately. Few substances are tracked more closely or stored more carefully than nuclear waste, so the properties of the large cylindrical containers that hold spent fuel rods must be known to a high accuracy. A heavily clad container of irregular shape is hard to measure, and jobs like that often end up at NIST, the National Institute of Standards and Technology.

The high-bay area of NIST’s large-mass facility, with cylindrical containers brought in for calibration and metal reference masses in the foreground

The high-bay area of the large-mass facility, showing cylindrical containers brought for calibration. The metal disks in the foreground are reference masses ranging from 2,500 pounds to 30,000 pounds. The tent-like enclosures cover the reference masses, which are hand-cleaned before use. Image from NIST’s page.

How precise it is

Zeina Kubarych, who leads NIST’s Mass and Force Group, said the group can measure a 30,000 pound object to an uncertainty of less than one-tenth of a pound, around three parts in a million, and that it knew of no other facility in the world that calibrates this range of masses at this precision. The team had recently finished calibrating a set of six nuclear waste reference containers, called replica mass standards, from 1,400 pounds to 32,500 pounds, for U.S. Enrichment Corporation. These serve as reference standards for calibrating working units.

A series of measurements can take several hours, according to Mass and Force scientist Kevin Chesnutwood. Weights must be placed on the scale the same way every time for the best repeatability. Each measurement is also corrected for factors such as air buoyancy, which depends on the weather, using a real-time air density calculated from barometric pressure and relative humidity. The balance-beam scale, with its many knife edges, is also affected by the weather and sits in a very stable environment. It is rated for a maximum load of nearly 28,000 kilograms (approximately 61,000 pounds).

Other work

Nuclear canisters are a comparative rarity. Most of the facility’s work is calibrating reference weights, often used in deadweight machines, which in turn calibrate load cells that turn mechanical force into electrical signals. The group calibrated a set of weights and several load cells from Boeing that served as reference standards in stress tests of the airframe of the 787 Dreamliner, and has done similar jobs for the U.S. Army and the Department of Agriculture. Customers often want weights adjusted to a given mass as well, usually by adding material to adjustment cavities in the weights, which are then sealed; it takes several rounds of measurement. The group also advises people designing deadweight machines.

A chain back to the kilogram

Everything must be traceable to the U.S. primary national standard, the platinum-iridium artifact K20, one of the original 1884 replicas of the International Prototype Kilogram. K20 itself was recalibrated in 2010 against the international prototype. So any change in the group’s standards means a chain of calibrations from K20, stepping from 1 kg to 2 kg, 5 kg, 10 kg, 20 kg, 50 kg and so on, up to 500 pounds, then onward to fully calibrated 20,000 pound and 30,000 pound standards. Combinations of these let the team use the balance’s full capacity. Very large masses are often expressed in pounds for historical reasons.

In 2010 the group acquired new standard masses, all stainless steel with well-characterized densities, because some older large masses were cast steel and not stable enough over time. The old sets were decommissioned, but first the new ones had to be calibrated all the way from the prototype, which was finished in December 2012. Chesnutwood said that working up and down from the kilogram to all the working standards would take a solid six months if nothing else were done, and up to two years in practice. With the new standards and statistical process control in all measurements, the group’s uncertainties have improved over the past 10 years.

The facility was designed to allow periodic recalibration of the many 50,000 pound masses used in NIST’s million-pound (4.448 meganewton) deadweight machine, but it soon gained many industry customers. Handling objects that big and not of nominal size and shape is one of its most challenging jobs, Chesnutwood said; every large-mass job is something of a special case, and the team needs to know how customers will use the measurements.

Sources

Комментарии

Spinner Logo

Ещё на тему «Наука»

Автор: Hub Nexus editors
Top 10 in AI, week of 26 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 19 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 12 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 2 November 2026
CC BY 4.0
Adaptive Evolution
CC0 1.0 (общественное достояние)
FEQinput helps hydrologists read, search, edit and run input files for FEQ, the USGS model of unsteady flow in open channels, showing descriptions of input lines to help new users overcome a steep learning curve.