Monitoring Methods for the Shoshone River at Kane, Wyoming

Two people on a bridge next to a small crane with the crane arm hanging out over a river.

A crane, reel, and DH-95 suspension sampler set up on the Hwy 37 bridge at the Shoshone River. NPS

Water Chemistry

The Greater Yellowstone Inventory and Monitoring Network collects water samples quarterly generally following depth and width-integrated protocols outlined in the U.S. Geological Survey (USGS) National Field Manual for the Collection of Water-Quality Data.

In wadeable depths, we use a 1-L, hand-held DH-81 sampler affixed to a 1-m wading rod to collect depth and width-integrated water samples. During non-wadeable flows, samples are collected from a bridge using a bridge-board or crane, reel, and DH-95 suspension sampler. At multiple locations along the river's cross-section, we collect water using vertically integrated sampling techniques. Samples from the 1-L bottle are mixed into an 8-L churn splitter; we use the churn splitter to homogenize and dispense a representative subsample into laboratory provided bottles. These bottles are then shipped overnight or delivered to an EPA-certified commercial lab for processing.

A water quality measuring instrument on the river shore attached to a wire that extends out into the water

We use a multi-parameter instrument to measure core water quality parameters at the monitoring site. NPS

Core Water Quality Parameters

In addition to water samples, water quality parameters (temperature, specific conductance, dissolved oxygen, pH, and turbidity) are collected in situ using a handheld, multi-parameter instrument (e.g., YSI EXO 1 sonde) at four representative locations on the river cross-section. Collection of water sample core parameters and rationale for testing nutrients and suspended solids is described in the approved Greater Yellowstone Network Regulatory Water Quality Monitoring Protocol (O'Ney 2006).

River Discharge

Discharge (river flow estimates) and water temperature data from the Shoshone River sampling location are available online from the U.S. Geological Survey's National Water Information System and listed under station USGS 06285100. The station is near Lovell, Wyoming.

Greater Yellowstone Network Water Resources Protocols

Read the full protocols and standard operating procedures for water quality and discharge here.

Protocols and Standard Operating Procedures

Source: NPS DataStore Collection 7853. To search for additional information, visit the NPS DataStore.

Part of a series of articles titled
Water Resources Monitoring in the Shoshone River at Kane, Wyoming, 2019.

Previous:
Shoshone River Water Quality at Kane, Wyoming

Next:
Water Quality Criteria for the Shoshone River at Kane, Wyoming

Where this belongs

  • Bighorn Canyon National Recreation Area

Where this page came from

This page was imported from National Park Service. Produced by the U.S. National Park Service and, as a work of the United States government, in the public domain.

Nobody has written it yet — it is the source material at a new address, which is why search engines are asked to skip it and why no one earns from it. It is up for grabs: take it on, and it is yours to rewrite and to earn from.