Monitoring Methods for the Lamar River near Tower Ranger Station, Wyoming

A scientist holding a rod attached to a bottle that is submerged under water in a river

A 1-m wading rod is attached to a DH-81 hand-held sampler to collect water samples across the Lamar River. NPS

Water Chemistry

The Greater Yellowstone Inventory and Monitoring Network collects water samples monthly during ice-free periods generally following depth and width-integrated protocols outlined in the U.S. Geological Survey (USGS) National Field Manual for the Collection of Water-Quality Data.

We use a 1-L, hand-held DH-81 sampler affixed to a 1-m wading rod to collect depth and width-integrated water samples. At multiple locations along the river's cross-section, we collect water using vertically integrated sampling techniques. Samples from the 1-L bottle are mixed into an 8-L churn splitter; we use the churn splitter to homogenize and dispense a representative subsample into laboratory-provided bottles. These bottles are then shipped overnight to an EPA-certified commercial lab for processing.

A scientist holding a piece of equipment that is submerged in river water.

A handheld, multi-parameter instrument is used to collect water quality parameters: temperature, specific conductance, dissolved oxygen, pH, and turbidity. NPS

Core Water Quality Parameters

In addition to water samples, water quality parameters (temperature, specific conductance, dissolved oxygen, pH, and turbidity) are collected in situ using a handheld, multi-parameter instrument (e.g., YSI EXO 1 sonde) at four representative locations on the river cross section. Collection of water sample core parameters and rationale for testing nutrients and suspended solids is described in the approved Greater Yellowstone Network Regulatory Water Quality Monitoring Protocol (O'Ney 2006).

River Discharge

Discharge (river flow estimates) and water temperature data from the Lamar River sampling location are available online from the U.S. Geological Survey's National Water Information System and listed under station USGS 06191500. The station is near Tower Ranger Station, WY.

Greater Yellowstone Network Water Resources Protocols

Read the full protocols and standard operating procedures for water quality and discharge here.

Protocols and Standard Operating Procedures

Source: NPS DataStore Collection 7853. To search for additional information, visit the NPS DataStore.

Part of a series of articles titled
Water Resources Monitoring in the Lamar River near Tower Ranger Station, Wyoming, 2021.

Previous:
Water Quality in the Lamar River near Tower Ranger Station, Wyoming

Next:
Water Quality Criteria for the Lamar River near Tower Ranger Station, Wyoming

Where this belongs

  • Yellowstone National Park

Where this page came from

This page was imported from National Park Service. Produced by the U.S. National Park Service and, as a work of the United States government, in the public domain.

Nobody has written it yet — it is the source material at a new address, which is why search engines are asked to skip it and why no one earns from it. It is up for grabs: take it on, and it is yours to rewrite and to earn from.