Hub Nexus
업데이트됨

작가아직 작성자가 없습니다맡기

개선할 점이 보이나요? 변경을 제안하세요.

후원

In a wide-ranging analysis of the effects of weathering and biological degradation on ignitable liquids, researchers at the University of Central Florida’s National Center for Forensic Science studied 50 liquids in the Ignitable Liquids Reference Collection (ILRC) database. The study, supported by the National Institute of Justice, was the most comprehensive analysis of the effects of weathering and biological degradation yet done, the researchers said. The results were included in the ILRC database, and a “best practices” statement was developed to “inform forensic practice and policy in laboratories conducting fire debris analysis.”In the aftermath of a fire, investigators often face the daunting task in trying to determine if ignitable liquids such as gasoline or other solvents were involved in starting the blaze. Discovering and identifying flammable liquids after a fire is more difficult due to the effects of weathering, primarily through evaporation of volatile compounds, and biological degradation, which can alter the chemical signature of the liquids.

The ignitable liquids studied, representing the many “designated classes” of the American Society for Testing and Materials (ASTM) International, ranged from gasoline to oxygenated liquids. Each liquid was “weathered” by removing various amounts of the original volume to simulate evaporation. Biological degradation was accomplished by placing small amounts of the liquids in potting soil and allowing them to degrade for time periods running up to 21 days.

Researchers said that the underlying concern was the possibility that weathering and biological degradation “would lead to failure to identify the presence of an ignitable liquid reside.” Not only could these factors mislead analysts, they could “decrease the ability of automated techniques to properly assign liquids into ASTM classes” the researchers said.

Since the study concluded, the results on how to better identify weathered and biologically degraded liquids have been made available on the ILRC database web site and have “had an impact on fire debris analysis practices and policy within individual laboratories.”

About This Article

The research described in this article was funded by NIJ cooperative agreement number 2011-DN-BX-K539, awarded to the University of Central Florida. This article is based on the grantee report “Degraded Ignitable Liquids Database: An Applied Study of Weathering and Bacterial Degradation on the Chromatographic Patterns of ASTM E 1618 Ignitable Liquid Classes” (pdf, 105 pages), by Michael Sigman and Mary Williams, University of Central Florida.

Where this page came from

This page was imported from National Institute of Justice. Published by the National Institute of Justice, U.S. Department of Justice, whose content is not copyrighted (its reuse policy); its pictures, stock photography, are not copied.

Nobody has written it yet — it is the source material at a new address, which is why search engines are asked to skip it and why no one earns from it. It is up for grabs: take it on, and it is yours to rewrite and to earn from.

언어English

이용 허락: CC0 1.0 (퍼블릭 도메인) · 출처 nij.ojp.gov

1

0

0

0

Spinner Logo

코멘트

Spinner Logo
버전: 2CC0 1.0 — public domain
The runaway star that left the Tarantula Nebula
버전: 2CC0 1.0 — public domain
The Blackwell School, where segregation had no law behind it
버전: 2CC0 1.0 — public domain
The Eagle Nebula, seen in the infrared
버전: 2CC0 1.0 — public domain
The house where the Equal Rights Amendment was written
버전: 2CC0 1.0 — public domain
The Aleutians, the forgotten front of the Second World War
버전: 2CC0 1.0 — public domain
The Cosmic Cliffs are not cliffs