EPA tested how to clean up after an indoor chemical warfare agent release by simulating one inside a building. At the Operational Test and Evaluation of Chemical Remediation Activity (OTECRA), held at the Muscatatuck Urban Training Center in Indiana, EPA researchers and emergency responders worked through contamination, sampling, decontamination, waste and data handling together. Chemical warfare agents are chemicals used to cause intentional death or harm through their toxic properties, and EPA says they remain a threat to the United States and other countries.

EPA contractors analyzing samples in the PHILIS lab. Image from EPA’s page.
The test setting
Part of a building’s interior was set up to look like an office and a studio apartment, with items that would need cleaning after a real incident: wall materials, tables, IT equipment, countertops and kitchen appliances. The exercise followed a sequence: initial contamination, sampling before decontamination, decontamination, sampling afterwards, with waste and data management throughout.
It built on bench-scale and pilot-scale research that had informed surface wipe sampling, wet-vacuum sampling and the choice of decontaminants. It also brought in EPA assets. EPA’s Portable High-throughput Integrated Laboratory Identification System (PHILIS) analyzed samples on site, as it would in an emergency response. Air monitoring units were set up for demonstration to check for volatile hazards, and readings were recorded on the hand-held detectors EPA Regions currently use, so On-scene Coordinators could judge how well they work.
Contamination

Taking samples from a floor surface. Image from EPA’s page.
The simulant was malathion, an insecticide commonly used in research in place of organophosphorus agents such as VX. It was applied as liquid droplets to hard, non-porous surfaces such as furniture, floors and walls. EPA received a categorical exclusion under NEPA for the test because malathion is not authorized for indoor use. The area was isolated with caution tape as an exclusion zone. Stainless-steel coupons placed in each room beforehand were retrieved after contamination and shipped to EPA’s laboratory in Research Triangle Park, NC, to measure relative contamination.
Sampling before and after
The day after contamination, teams sampled to establish how much malathion was on surfaces, which helps responders plan remediation with confidence. Non-porous surfaces were wiped with pre-wetted cotton gauze and analyzed on site by PHILIS, which can give decision-makers next-day results. Larger floor samples were collected by wet-vacuum and shipped to an external commercial laboratory. EPA’s Environmental Sampling and Analytical Methods Program (ESAM) guided the choice of analytical methods so that every laboratory followed a standard process. After decontamination, a second round of sampling showed whether any malathion remained; comparing the two showed whether the approach worked.
Decontamination

Spraying down a table with decontaminant. Image from EPA’s page.
| Round | Decontaminant | Application |
|---|---|---|
| 1 | Decon7, an activated hydrogen peroxide product | Low-pressure spraying system |
| 2 | Undiluted bleach | Sprayed in a similar way |
The sprayers are commercially available and need no extensive training. Before leaving the exclusion zone, responders and equipment went through a contamination reduction zone: personnel walked a line where diluted bleach was applied to all protective equipment, followed by a water rinse and patting dry, and samples were wiped with a bleach wipe.
Data and waste
Each sample container carried a QR code. Using EPA’s Simple QUIck Read Label (SQUIREL) tool, researchers gave each sample a unique ID, scanned it on tablets, and entered the collection method, sample type, matrix, start and end times, observations and photographs into Esri’s Field Maps. The data went to EPA’s Geoplatform, which generated a chain-of-custody form for each shipment. Portable Wi-Fi boxes made this work in an area with weak signal, which is likely after a major disaster.

Samplers walking through the line where diluted bleach was applied to all PPE. Image from EPA’s page.
Proper management of waste from a chemical warfare agent event is vital to remediation, because different decontamination strategies produce different waste quantities and types, which affect the timeline, resources and cost. Before the exercise, EPA’s DeconST and I-WASTE tools estimated the waste expected before and after decontamination, plus waste from decontaminating personnel. All waste was contained, segregated and staged for characterization, sampling and disposal by EPA’s Region 5. Results of the decontaminant’s performance fed the waste acceptance criteria and disposal options that such incidents require, and the analysis went to disposal facilities in Ohio and Indiana for approval.
What comes next
The OTECRA team wrote up what worked and what did not, with operational and research gaps, in the report “Operational Test and Evaluation of Chemical Remediation Activities”. The Emergency Response Research Webinar series hosted a presentation on the field study on August 14, 2024. EPA says the full-scale test raises responders’ confidence in sampling and decontamination methods, and that close collaboration between researchers and responders builds national capability.