Three reputable 30-year satellite datasets show temperature trends in the middle troposphere that differ by a factor of three in magnitude. A National Institute of Standards and Technology (NIST) team says part of the cause is that microwave sensors have no accepted standard for calibration, and it describes a method to build one.

The problem

Much of what is known about decadal climate change, and much of the weather forecast, comes from satellites measuring microwave radiation at different levels of the atmosphere. Satellites do not measure temperature directly. They record the radiation reaching their sensors at key wavelengths, and groups process it in various ways into temperature equivalents, reported as brightness temperature. But there is no accepted brightness-temperature standard for authoritative calibration, for resolving differences between satellites or for comparing programs. Weather and climate uses need the temperature accurate to within 1 kelvin or less, yet David Walker, project leader for microwave remote sensing in the Electromagnetics Division of NIST's Physical Measurement Laboratory (PML), says new data from nominally identical instruments can differ by a couple of kelvin. Researchers get good results with a tremendous amount of post-processing and recalibration tricks, and still with more uncertainty than they would like.

Such gaps matter for the planned Global Earth Observation System of Systems, a worldwide network whose goals include common technical standards so that data from thousands of instruments can be combined. Internationally recognized, traceable standards would reduce uncertainty and help reconcile instrument records over years or decades. They would also guard against "data gaps," where records from different instruments do not overlap because of instrument failure (including launch failure), delays or other causes.

The approach

The international scientific community uses the International System of Units (SI) for this kind of problem: measurements traceable to the SI can be shown to be equivalent across instruments, places and times. Walker's group is developing SI-traceable radiometric measurements of the brightness temperature (TB) of a microwave source, the temperature an ideal blackbody would need in order to emit the radiance arriving at the sensor. A TB standard can be a source (radiance standard) or a receiver (irradiance standard, a radiometer). PML is working on a source standard with the University of Colorado and NASA Goddard Space Flight Center, and significant progress has been made, but it is not finished.

NIST waveguide radiometers; the cryogenic primary standards are inside the blue cylinders

NIST waveguide radiometers. The cryogenic primary standards are encased in the blue cylinders. Image from NIST's page.

The receiver standard has been demonstrated at NIST. Its key advance is that the measurements can be made in free space without separately characterizing the antenna beam pattern. Walker's group worked out how to find a receiver antenna's beam efficiency, the fraction of the antenna's power pattern covered by the target, and so the target's TB, by varying the target's temperature and its distance from the antenna.

The test

The test was done in NIST's anechoic chamber in Boulder, Colorado, with a blackbody target 33 cm across and a rectangular horn antenna. The target's temperature was raised in steps of approximately 10 K from 296 K to 352 K, monitored by calibrated thermometers in its back, and the distance from target to receiver varied from 50 cm to 500 cm. Three frequencies, 18 GHz, 22.5 GHz and 26 GHz, were measured in every configuration. The result so far is an uncertainty of 0.7 K between 18 GHz and 26.5 GHz, well inside the permissible range for troposphere, stratosphere, precipitation and water vapor measurements. The team concludes that the procedure suits pre-launch calibration of blackbody targets at microwave frequencies.

A receiver with a horn-like waveguide measuring radiance from a blackbody target in the anechoic chamber

In NIST's anechoic chamber in Boulder, the receiver at left measures radiance from the blackbody target at right, at a distance of approximately 1.5 m. The target's actual temperature is measured with multiple platinum resistance thermometers. Image from NIST's page.

Why microwaves

Walker notes that most satellite data are at optical frequencies, but microwaves add something: total, continuous coverage of the Earth, since microwave sensors can see through clouds, and quantitative information about moisture in the atmosphere. Sea-level change is measured by radar altimetry with an accuracy of a few millimeters, but those measurements depend on correcting for moisture-related path delays that can reach a few centimeters, and the path delay is measured with passive microwave radiometry, which is what NIST's research addresses.

Sources

Комментарии

Spinner Logo

Ещё на тему «Наука»

Автор: Hub Nexus editors
Top 10 in AI, week of 26 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 19 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 12 October 2026
Автор: Hub Nexus editors
Top 10 in AI, week of 2 November 2026
CC0 1.0 (общественное достояние)
Delta 2020 Intensifies into a Major Hurricane
CC0 1.0 (общественное достояние)
Restored Corals are Thriving Three Years after Hurricane Matthew