- Licence
- CC BY-SA 4.0Adapted from en.wikibooks.org
- Languages
- English
- Topics
- Education
- Publications
- Basic Physics of Digital Radiography
A quiz on X-ray production & their interactions with matter is available below for those who wish to test their knowledge and understanding of these topics.
Additional quizzes are also available on:
X-Ray Production & Interactions with Matter
| Point added for a correct answer: | |
|---|---|
| Points for an incorrect answer: | |
| Ignore the questions' coefficients: | |
1
In soft tissue, Compton scattering becomes the most important interaction process above:
| 5 keV. | |
|---|---|
| 25 keV. | |
| 50 keV. | |
| 75 keV. |
2
The intensity of an X-ray beam increases and the subject contrast remains unchanged by:
| Increasing the kVp. | |
|---|---|
| Decreasing the filtration in the beam. | |
| Changing from a single phase generator to a three phase one. | |
| Increasing the exposure (mAs). |
3
As the kV is increased, the contrast between soft tissue and bone seen in a radiographic image:
| Decreases up to 69.5 kV but thereafter increases due to tungsten K-radiation. | |
|---|---|
| Increases up to 69.5 kV but then remains constant. | |
| Increases above 80 kVp, especially in Computed Radiography. | |
| Decreases regardless of the choice of image receptor. |
4
If an aluminium filter 5 mm thick transmits 25% of a monoenergetic X-ray beam, then 10 mm will transmit:
| 0%. | |
|---|---|
| 2%. | |
| 5%. | |
| 6.25%. |
5
Increasing filtration reduces the intensity of the X-ray spectrum:
| Equally at all photon energies. | |
|---|---|
| Only at the lower photon energies. | |
| Mostly at the lower photon energies. | |
| Mostly at the higher photon energies. |
6
In comparison with a single phase HV generator of the same kVp, the effective energy of the X-rays from a medium frequency generator is:
| Higher. | |
|---|---|
| Lower. | |
| The same. | |
| Twice. |
7
The anode of a diagnostic X-ray tube is angled to give:
| Proper reflection of the electron beam. | |
|---|---|
| A smaller actual focal spot. | |
| A smaller effective focal spot. | |
| Higher beam homogeneity. |
8
Unlike the energy of a X-ray photon, that of a photoelectron is initially lost:
| In a single interaction. | |
|---|---|
| As heat. | |
| As a result of multiple ionizations. | |
| By conversion into photons of energy 511 keV. |
9
For fixed kVp and filtration which will produce a beam with the largest Half Value Layer (HVL):
| Constant potential generator. | |
|---|---|
| Single phase generator. | |
| Mobile capacitor discharge unit. | |
| The HVL would be the same for all three. |
10
The Compton scattering probability per electron is approximately:
| Independent of Z. | |
|---|---|
| Proportional to Z. | |
| Proportional to Z 2 . | |
| Proportional to 1/Z 2 . |
11
The design of an intensifying screen is a compromise between the twin desires of low patient dose and low quantum mottle. Which of the options below best satisfies this compromise:
| High detection efficiency (DE) and high conversion efficiency (CE). | |
|---|---|
| High DE and low CE. | |
| Low DE and high CE. | |
| Low DE and low CE. |
12
A modulation transfer function equal to 1.0 at a particular spatial frequency (f) means:
| The high voltage ripple transmitted from mains fluctuations is 1%. | |
|---|---|
| The energy transferred to tissue is equal to that of the incident radiation. | |
| The electronic circuit utilised with automatic brightness control is set to perfect linearity. | |
| The diagnostic image perfectly reproduces contrast variations in the object radiographed at that spatial frequency. |
13
The scattered radiation during a diagnostic X-ray examination arises mainly as a result of the:
| Compton effect. | |
|---|---|
| Photoelectric absorption. | |
| Coherent scattering. | |
| All of these. |
14
Electrons striking the tungsten anode of an X-ray tube with 80 keV energy can produce:
| Bremsstrahlung X-rays of maximum energy 80 keV. | |
|---|---|
| Bremsstrahlung X-rays of average energy of 80 keV. | |
| Characteristic X-rays of 80 keV. | |
| No characteristic X-rays whatsoever. |
15
The finite size of the X-ray tube focal spot gives rise to:
| Pseudo-linear transformation. | |
|---|---|
| Quantum mottle. | |
| Penumbra. | |
| Magnification. |
16
The X-ray tube current (mA) influences which ONE of the following parameters:
| Maximum X-ray energy? | |
|---|---|
| Number of X-ray photons? | |
| Mean energy (quality) of the X-rays? | |
| Patient penetration? |
17
The proportion of the energy of an electron beam incident on the X-ray tube anode that is converted into X-rays is about:
| 0.2%. | |
|---|---|
| 2.0%. | |
| 4.0%. | |
| 20%. |
18
The X-ray tube current is dictated by:
| The anode speed of rotation. | |
|---|---|
| The size of the focal spot. | |
| The filament current. | |
| The filament current and the kilovoltage. |
19
For the photoelectric effect, the absorption per unit mass of the absorber depends approximately on the atomic number (Z) of the absorber according to:
| 1/Z. | |
|---|---|
| Z. | |
| Z 3 . | |
| Z for kV less than 50 and Z 2 for kV greater than 50. |
20
To reduce image noise by a factor 10 the number of information carriers (i.e. X-rays photons) must ideally be increased by a factor of :
| 3.1. | |
|---|---|
| 10. | |
| 20. | |
| 100. |
21
Which ONE of the following statements is false?
| The LSF stands for line spread function. | |
|---|---|
| Veiling Glare reduces the width of the LSF. | |
| The LSF is obtained from an analysis of a radiograph of a slit. | |
| The MTF can be obtained from a Fourier transformation of the LSF. |
22
When a filter is used to harden a diagnostic energy X-ray beam, it does so mainly by:
| Compton effect. | |
|---|---|
| Photoelectric absorption. | |
| Unaltered scatter. | |
| Coherent scattering. |
23
An X-ray beam with a high HVL is:
| Said to be more penetrating. | |
|---|---|
| Likely to result in a larger skin absorbed dose. | |
| Said to be soft. | |
| Less likely to produce scatter. |
24
A radiograph is taken of a kidney using a SID of 100 cm with the kidney 50 cm from the plane of the image receptor. The kidney shadow is 24 cm long. The length of the kidney is approximately:
| 12 cm. | |
|---|---|
| 24 cm. | |
| 36 cm. | |
| 48 cm. |
25
The term photon was coined to apply to:
| A small wave packet or bundle of electromagnetic radiation. | |
|---|---|
| An accelerated electron (in the diagnostic range). | |
| Any electron emitted from the photo-sensitive surface of an image intensifier tube. | |
| The collimated X-ray beam. |
26
The type of X-ray interaction with matter in which all of the energy of the incident photon is expended in dislodging a bound electron is called:
| Photoelectric effect. | |
|---|---|
| Compton effect. | |
| Pair. | |
| None of above. |
27
The inverse square law relationship between radiation intensity and distance from a point source of radiation (e.g. XRT focal spot) is due to:
| Chance. | |
|---|---|
| Scatter in air. | |
| Absorption in air. | |
| Divergence of the X-ray beam. |
28
The Compton absorption probability per electron is approximately:
| Independent of Z. | |
|---|---|
| Proportional to Z. | |
| Proportional to Z 2 . | |
| Proportional to 1/Z 2 . |
29
The effect on the X-ray spectrum of reducing the anode angle is similar to that of:
| Increasing filtration. | |
|---|---|
| Increasing kV. | |
| Decreasing kV. | |
| Increasing mAs. |
30
In Compton scattering:
| The energy is shared between a recoil electron and an emitted photon. | |
|---|---|
| All excess energy is given to an ejected electron. | |
| The energy is shared between a scattered photon and a recoil electron. | |
| The photon is re-emitted with the same energy but at another angle. |
31
For bone, X-ray attenuation is predominantly due to:
| Photoelectric effect, at energies than 75 keV. | |
|---|---|
| Photoelectric effect, at energies greater than 50 keV. | |
| Compton scatter, at energies greater than 25 keV. | |
| Compton scatter, at energies greater than 50 keV. |
Where this page came from
This page was imported from Wikibooks. From “Basic Physics of Digital Radiography” on Wikibooks, by its contributors, under CC BY-SA 4.0. Changed here: set as a page; navigation and edit links left out; each image under its own licence, credited in its caption.
Nobody has written it yet — it is the source material at a new address, which is why search engines are asked to skip it and why no one earns from it. It is up for grabs: take it on, and it is yours to rewrite and to earn from.
Get each new page of
Basic Physics of Digital Radiography
Following means one email when a page is added, nothing when a page changes.
Comments