Skip to content
Hub Nexus

No author yetClaim it

Version 3Updated 2 min read

Support

In July 1945 the United States tested the first atomic bomb, named Trinity, in New Mexico. The test was not declassified until 1949, when Geoffrey Ingram Taylor released two papers showing how he calculated the bomb's energy yield from pictures of the explosion alone. A paper on arXiv revisits his method, using modern computer vision tools to measure the blast radius more precisely and curve fitting and numerical integration for the rest.

The Trinity explosion

The Trinity explosion, as shown in the paper, which cites the National Park Service's Trinity site page.

The background

Trinity took place on July 16, 1945, a month before the bombs fell on Hiroshima and Nagasaki. The blast reached 40,000 feet in only 7 minutes. Engineering courses often present Taylor's work as an application of dimensional analysis with the Buckingham Pi theorem. The paper stresses that this is not what he did: he started from underlying equations and introduced simplifications alongside observations to work out the quantity he wanted.

Taylor is usually credited with the calculation because he alone proved the point-source model valid and gave the energy within a range of error. John von Neumann and Leonid Sedov made similar calculations and reached better accuracy. Their results, with later estimates:

AuthorEnergy (kilotons TNT)
Taylor16.8
Sedov, von Neumann16.9
Deakin17.5
Hanson22.1
Truman20
Groves15-20

Taylor's, Deakin's, Sedov's and von Neumann's results assume the specific heat ratio γ is constant at 1.4. Hanson used physical samples from the explosion to work out the amount of plutonium and other components. Truman's and Groves's figures were released after declassification.

The dimensional-analysis shortcut

Treat the blast as a point source expanding as a spherical shock wave. Energy then depends on the air's undisturbed density, the shock radius and the time since the blast, in the form E = K ρ₀ R⁵ t⁻², where K is a constant that Taylor showed depends on γ. Taylor himself got this form from first principles and similarity assumptions, which let him pin down K.

What the new analysis found

The authors followed Taylor's approach with modern techniques. For the larger of the two radii, their results agree very well with Taylor's and lie within the acceptable energy range for γ between about 1.2 and 1.4, the range Taylor judged likely. Agreement with the accepted estimate is best between 1 and 3 ms, as expected from the point-source solution. At later times, between 3.53 and 4.61 ms, their energies differ from those using Taylor's radii and times, because the images are unclear and the window does not show the whole blast, so a radius had to be assumed. Since radius is raised to the fifth power, a difference of about 2.3 m at 3.53 ms means an energy difference of around 3,000 tons.

The authors conclude that Taylor's approximation was very good, then and now. They hope the paper shows how to combine governing equations with image data without costly simulations, and how dimensional analysis can give quantitative insight. Their code and annotation files are on GitHub.

Sources

  • Revisiting Taylor and the Trinity Test, arXiv:2403.19657, licensed CC BY 4.0. Changed here: reworded and shortened; notation, derivations, figures other than the Trinity photograph and references left out; rewritten in hubnx's own words.
  • Authors of the original: Elizabeth Mone, Pranay Seshadri.

Comments

Spinner Logo

More on Science

By Hub Nexus editors
Top 10 in AI, week of 2 November 2026
By Hub Nexus editors
Top 10 in AI, week of 26 October 2026
By Hub Nexus editors
Top 10 in AI, week of 19 October 2026
By Hub Nexus editors
Top 10 in AI, week of 12 October 2026
CC0 1.0 (public domain)
Achromatopsia